Chapter 3: FRU Removal and Replacement Procedures
Replacing Node Expansion Cards
Quantum DXi6900-S Field Service Manual
101
Slot 4 (top)
l
Dual port 10 GbE (SFP+) Ethernet ports (X520)
l
Dual port 10 GBase-T Ethernet port (X540)
l
Dual port 16 Gb Fibre Channel (QLogic)
for DXi6900-S card configuration options.
Slot 5 (bottom)
l
Dual port 10 GbE (SFP+) Ethernet ports (X520)
l
Dual port 10 GBase-T Ethernet port (X540)
l
Dual port 16 Gb Fibre Channel (QLogic)
for DXi6900-S card configuration options.
Expansion Card Riser 3
Slot 6 (top)
No card
Slot 7 (bottom)
l
Dual port 10 GbE (SFP+) Ethernet ports (X520)
l
Dual port 10 GBase-T Ethernet port (X540)
l
Dual port 16 Gb Fibre Channel (QLogic)
for DXi6900-S card configuration options.
Caution:
Use appropriate ESD precautions, including the use of a grounding strap, when performing
this procedure.
Removing and replacing an expansion card in expansion card riser 2 or riser 3 includes the following steps:
l
Removing an Expansion Card from Riser 2 or 3 below
l
Installing an Expansion Card in Riser 2 or 3 on page 104
Removing an Expansion Card from Riser 2 or 3
To remove a failed expansion card from riser 2 or 3:
Turning Off the DXi6900-S on page 21
).
Opening and Closing the Node on page 63
).
3. Disconnect any cables connected to the expansion card.
4. Holding the touch points, lift the expansion card riser 2 or 3 from the riser connector on the system board
).