Chapter 3: FRU Removal and Replacement Procedures
Replacing the Node Integrated Storage Controller Battery
Quantum DXi6900-S Field Service Manual
111
Identifying a Failed Integrated Storage Controller Battery
The integrated storage controller (Dell PERC H730) includes a battery that protects the RAID controller
during power failures. The battery allows the RAID controller to store any cached data until power can be
restored.
To identify a failed integrated storage controller battery:
1. Access the remote management console (see
Accessing Remote Management on page 21
).
2. Navigate to the
Status > Hardware > Details > Storage Arrays
page.
3. Under
Storage Arrays
, click
a0
, and then click
Batteries
and note the PERC H730 battery status
).
Figure 74:
Checking Integrated Storage Controller Battery Status
Removing a Failed Integrated Storage Controller Battery
To remove the integrated storage controller battery from the DXi6900-S Node:
Turning Off the DXi6900-S on page 21
).
Opening and Closing the Node on page 63
).
3. Remove the integrated storage controller (see
Replacing the Integrated Storage Controller on
).
4. Unplug the battery cable and remove the battery from the integrated storage controller (see
).