Chapter 1: Basic Operations
Turning On and Shutting Down the System
Quantum DXi6900-S Field Service Manual
19
Items
Button/LED
Description
3
Ethernet link rate (green)
Solid
- port speed 1000MB/sec.
Off
- port speed 10/100MB/sec.
4
Ethernet activity (green)
Solid
- link established.
Blinking
- indicates port activity.
5
Service action allowed (blue)
Solid
- safe for Quantum field service. to remove ESM
from slot.
6
Service action required (amber)
Solid
- ESM has failed and requires attention.
Note:
Fault light will be on during power up and
will turn off after self-test sequence completes.
7
Power (green)
Solid
- power is being applied to the ESM.
8
Seven segment display (green)
Displays tray ID and error code. (Displays
00
when the
Array module is operating normally.)
9
Standby power (green)
Solid
- main DC power is off and 5V standby power is
on.
10
DC enabled (green)
Solid
- DC power rails are within specified limits.
11
Service action allowed (blue)
Solid
- safe for Quantum field service. to remove power
supply from slot.
12
Service action required (amber)
Solid
- power supply has failed and requires attention.
13
AC enabled (green)
Solid
- power is being applied to the power supply and
the power switch is on.
14
Power switch
Module power switch.
Turning On and Shutting Down the System
To turn on or shut down the DXi6900-S, refer to the following sections:
l
Turning On the DXi6900-S on the next page
l