Adjusting the Images That Were Taken
FQ2 User’s Manual
79
3
Taking
Image
s
• Detailed Settings for Search Position Compensation
The settings for the Search Position Compensation item are almost the same as those for the Search
inspection item. Only the [Multi-point output] setting of the Search item is not included in the settings of the
Search Position Compensation item. Make the settings for teaching and the judgement conditions in the same
way as for the Search item. (
4-4 Inspecting with the Search Inspection Item: p. 95)
Also, the following settings are included only in the Search Position Compensation Item.
• Source Image
You can select the image to which to apply the results of position compensation processing.
Applying the Results of Position Compensation: p. 75
• Interpolation
You can select the precision of position compensation.
If you select [Bilinear], the precision of position compensation will increase.
[Image]
−
[Image adjustment]
−
[Search position comp.]
−
[Modify]
−
[Details]
−
[Scroll parameter]
−
[Interpolation]
The settings are the same as those for the Shape Search Position Compensation item.
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
2
Press [Model]
−
[Search position comp.]
3
Make any detailed settings as required for the position compensation processing.
Refer to Detailed Settings for Search Position Compensation, below.
4
Press [OK].
5
Press [Back].
Expression text string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG
DX
Scroll X
This is the amount of position com-
pensation for the X coordinate.
−
99,999.9999 to 99,999.9999
DY
Scroll Y
This is the amount of position com-
pensation for the Y coordinate.
−
99,999.9999 to 99,999.9999
X
Position X
This is the X coordinate of the position
where the model was found.
−
99,999.9999 to 99,999.9999
Y
Position Y
This is the Y coordinate of the position
where the model was found.
−
99,999.9999 to 99,999.9999
SX
Reference X
This is the X coordinate of the position
where the model was registered.
−
99,999.9999 to 99,999.9999
SY
Reference Y
This is the Y coordinate of the position
where the model was registered.
−
99,999.9999 to 99,999.9999
CR
Correlation
This is the correlation.
0 to 100
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......