Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
258
FQ2 User’s Manual
Parallel Judgement Outputs
You can set judgement conditions for parallel output and then output the judgement results for those conditions.
●
Setting the Items to Judge and the Judgement Conditions
You can assign up to 16 judgement results to and output them from the D0 to D15 signals.
As the items to judge, you can specify the measurement data from inspection items that can be output and the
calculation results from the expression settings.
Use the following procedure to set the items to judge and the judgment conditions.
(1)
Setting the Items to Judge
You can assign the parameters from the inspection items to the data output signals (D0 to D15).
The following procedure shows how to assign the measured position X of [0. Search] to D0.
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Par. Jdg Output]
−
[Basic] Tab Page
(2)
Setting the Judgement Conditions
[In/Out]
−
[I/O setting]
−
[Output data set]
−
[Par. Jdg Output]
−
[Basic] Tab Page
1
Press [Settings].
2
Press [I0.D0].
3
Press [IO. Search].
4
Press [Position X X].
5
If the inspection item allows multi-point output,
press the number ([0] to [30]) of the inspection result
for which to output the data from the list of inspec-
tion results.
To register something to D1 or higher, repeat this pro-
cess.
1
Press [Judgement condition].
2
Set the correlation range that is to be judged as OK.
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......