Menu Tables
FQ2 User’s Manual
425
Appe
ndi
ce
s
12
Sensor
set
ti
ngs
Dat
a out
put
Link dat
a out
put
Area
set
ti
ngs
Response
A
rea t
y
p
e
Sets the area to write execution results
from the Sensor.
Control outputs, command codes,
response codes, and response data
CIO Area (CIO) (default), Work Area
(WR), Holding Bit Area (HR), Auxiliary
Bit Area (AR), DM Area (DM), EM Area
(EM0 to EMC)
System
Ad
dress
Set the first address of the response area.
0 to 99999 (default: 100)
System
Ou
tp
u
t
A
rea t
y
p
e
Sets the area to write output data from
measurements.
Output data 0 to 31
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0)
EM Area (EM1)
:
EM Area (EMC)
System
A
ddre
s
s
Set the first address of the output area .
0 to 99999 (default: 200)
System
Output hand-
shake
Sets whether to establish an interlock
with the PLC when data is output.
No (default) or Yes
System
Retry details
Enables or disables retrying communications.
This can be set only when the communi-
cations type is set to a PLC Link.
ON or OFF (default)
System
Retry interval
Sets the interval for retrying communications.
This setting is enabled only when [Retry
details] is set to [ON].
This can be set only when the communi-
cations type is set to a PLC Link.
0 to 2,147,483,647 ms (default:10,000
ms)
System
Max output data
Sets the upper limit of the number of out-
put data to use for PLC Link outputs.
Any output data that is beyond this value
is discarded.
This can be set only when the communi-
cations type is set to a PLC Link.
32 to 1024 (default: 256)
System
Output data size Sets the data size to output for EtherNet/
IP output.
If the data size that is set is exceeded,
data will be output in more than one
transfer.
This can be set only when the communi-
cations type is set to EtherNet/IP.
32 bytes (default), 64 bytes, 128 bytes, or
256 bytes
System
Connection
mode
Sets the TPC connection mode.
TCP server (default) or TCP client
System
Refreshing task
period
Set the communications cycle for cyclic
tag data link communications for the
Vision Sensor.
4 to 10,000 ms (default:10 ms)
System
Timeout
Sets the timeout time when handshaking
is enabled.
0.1 to 120.0 s (default: 10 s)
System
Data output
period
Set the period for outputting measure-
ment results.
This parameter is displayed and can be
set only when [Handshake setting] is set
to [No].
2 to 5,000 ms (default: 40 ms)
System
GATE signal ON
period
Set the time to turn ON the GATE signal.
This parameter is displayed and can be
set only when [Handshake setting] is set
to [No].
1.0 to 1,000.0 ms (default: 20.0 ms)
System
Initialize
Initializes the Sensor settings and saved
data.
---
---
Restart
Restarts the Sensor.
---
---
Update
Updates the Sensor system to the most
recent data.
---
---
Menu command
Description
Setting range
Data
Refer-
ence
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......