External Reference Parameters
458
FQ2 User’s Manual
127
Mea-
sure-
ment
condi-
tions
Previous conversion
mode
Setting/Acqui-
sition
0: Previous conversion
mode OFF, 1: Previous con-
version mode ON
0
---
---
133
Candidate level
Setting/Acqui-
sition
0 to 100
60
---
---
134
Detec-
tion point
coordi-
nate
Detection point X
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
0
---
---
135
Detection point Y
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
0
---
---
136
Mea-
sure-
ment
condition
Sort condition
Setting/Acqui-
sition
0: Ascending order of corre-
lation value,
1: Descending order of cor-
relation value,
2: Ascending order of posi-
tion X,
3: Descending order of
position X,
4: Ascending order of posi-
tion Y,
5: Descending order of
position Y
1
---
---
138
Judge-
ment
condi-
tions
Judgement upper limit
for correlation
Setting/Acqui-
sition
0 to 100
100
---
Adjust judge-
ment
139
Judgement lower limit
for correlation
Setting/Acqui-
sition
0 to 100
60
---
Adjust judge-
ment
140
Judgement upper limit
for detection count
Setting/Acqui-
sition
0 to 32
32
---
Adjust judge-
ment
141
Judgement lower limit
for detection count
Setting/Acqui-
sition
0 to 32
0
---
Adjust judge-
ment
142
Judgement upper limit
for search coordinate X
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
143
Judgement lower limit
for search coordinate X
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
144
Judgement upper limit
for search coordinate Y
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
145
Judgement lower limit
for search coordinate Y
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
146
Judgement upper limit
for search angle
Setting/Acqui-
sition
−
180 to 180
180
---
Adjust judge-
ment
147
Judgement lower limit
for search angle
Setting/Acqui-
sition
−
180 to 180
−
180
---
Adjust judge-
ment
152
Mea-
sure-
ment
condi-
tions
Extraction condition, X
upper limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
153
Extraction condition, X
lower limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
154
Extraction condition, Y
upper limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
155
Extraction condition, Y
lower limit
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
161
Detection count
Setting/Acqui-
sition
1 to 32
32
---
---
170
Model mode
Setting/Acqui-
sition
0: Fast,1: Stable
0
---
---
External
refer-
ence
number
Category Data name
Setting/Acqui-
sition
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......