Inspecting with the Sensitive Search Inspection Item
FQ2 User’s Manual
4
Settin
g Up In
spections
115
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Sensitive Search]
−
[Details] Tab Page
−
[Output
parameter]
Increasing Measurement Position Accuracy
You can increase the accuracy of measurement positioning.
You can calculate down to four decimal places.
[Inspect]
−
[Inspection]
−
[Sensitive Search]
−
[Modify]
−
[Details] Tab Page
−
[Meas.
Parameter]
Select the Results to Output
You can use multiple conditions to determine which results to output from all the objects detected with a
correlation at the candidate level or higher.
Only the results that meet all the specified conditions are output.
[Inspect]
−
[Inspection]
−
[Sensitive Search]
−
[Modify]
−
[Details] Tab Page
−
[Meas.
Parameter]
• You can change the output form for each measurement value to one of the following settings.
Press [
]
−
[Result type] on the right of the display.
Absolute value (default): The measured coordinates are output as absolute values.
Relative value: The difference from the reference value is output.
1
Press [Sub-pixel] and select [Yes].
1
Press [Candidate level] and adjust the candidate lev-
el so that only objects higher than a certain correla-
tion are detected.
Extraction condition Range
Description
Candidate level
0 to 100
Only objects with a correlation that is higher than the
specified candidate level are output.
The processing time changes if you change the candidate level.
Note
Note
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......