Connecting a Previous Touch Finder (FQ-D30/D31) to the FQ2-S Sensor
492
FQ2 User’s Manual
12-5 Connecting a Previous Touch Finder (FQ-D30/D31) to the FQ2-S Sensor
If you update the previous FQ-D30/D31 Touch Finder to version 1.6 or higher, you can connect it to an FQ2-S
Sensor. However, the memory size that is required to use all of the filter items, position compensation items,
and inspection items exceeds the memory capacity of the previous FQ-D30/D31 Touch Finder, so you will not
be able to use all of the filter items, position compensation items, and inspection items that are provided in the
FQ2-S Sensor.
Therefore, it is necessary to select only the filter items, position compensation items, and inspection items that
you need to use and register them in the Sensor.
If you connect the Touch Finder without doing this, the Touch Finder may freeze as soon as it is connected or
during operation.
Apart from the filter items, position compensation items, and inspection items, you can use all of the functions
of the Sensor.
Download the update file for the Touch Finder (version 1.6 or higher) and the FQ Item Selector from the
member website, and then use the following procedures to update the Touch Finder and register the filter
items, position compensation items, and inspection items in the Sensor.
http://www.omron-cxone.com/vision_sys
• Updating the Touch Finder
1
Place the update file directly in the root folder of an SD card.
2
Insert the SD card into the Touch Finder.
3
Press
(Setup Mode) - [TF settings] - [Update].
The Touch Finder will be updated automatically.
Do not turn OFF the power supply until updating the Touch Finder has been completed.
The Touch Finder may not start normally if power is turned OFF during the update.
Important
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......