Inspecting with the Shape Search II Inspection Item
FQ2 User’s Manual
4
Settin
g Up In
spections
111
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or used
in calculations.
4-13 Calculations and Judgements Using Inspection Item Data: p. 155
Measurement Data That Can Be Logged
The following values can be logged as measurement data.
*
When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data: p. 208
Expression text string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error
CR[0] to CR[31]
Correlation
This is the correlation of the Nth
model that was found.
0 to 100
X[0] to X[31]
Position X
This is the X coordinate where the Nth
model was found.
−
99,999.9999 to 99,999.9999
Y[0] to Y[31]
Position Y
This is the Y coordinate where the Nth
model was found.
−
99,999.9999 to 99,999.9999
TH[0] to TH[31]
Angle
This is the angle in which the Nth
model was found.
−
180 to 180
SX
Reference X
This is the X coordinate of the position
where the model was registered.
−
99,999.9999 to 99,999.9999
SY
Reference Y
This is the Y coordinate of the position
where the model was registered.
−
99,999.9999 to 99,999.9999
ST
Reference angle
This is the angle when the model was
registered.
−
180 to 180
RX
Detection coordinate X
This is the X coordinate of the detec-
tion point when the model was regis-
tered.
−
99,999.9999 to 99,999.9999
RY
Detection coordinate Y
This is the Y coordinate of the detec-
tion point when the model was regis-
tered.
−
99,999.9999 to 99,999.9999
C
Count
This is the number of models found.
0 to 32
Parameter
Range of value
Description
Judgement
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
This is the measurement judgement results.
Correlation
0 to 100
This is the measured correlation.
Position X
−
99999.999 to 99999.999
This is the measurement position X.
Position Y
−
99999.999 to 99999.999
This is the measurement position Y.
Angle
−
180 to 180
This is the measurement angle.
Count
0 to 32
This is the number of models found.
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......