Wiring
FQ2 User’s Manual
2
In
sta
llatio
n
a
nd
Con
nection
s
45
FQ-SDU10/SDU15 Terminal Signal Names
*1:
Leave all signal terminals that are labeled “NC” open.
*2:
You can select whether to turn the external lighting ON (Positive) or OFF (Negative) when the signal turns ON. (The setting is called the
strobe output polarity.)
Changing the Output Timing and Output Time of the STGOUT Signal: p. 270
*3:
This control signal is used to turn ON external lighting when an image is taken. Connect this signal to external lighting.
*4:
This signal is output to an external device when exposure of the imaging elements is completed. If you want to move the Sensor to the next
measurement location after a measurement is completed, move the Sensor only after this signal turns ON.
Shutter Output Signal (SHTOUT)
Pin
Signal
IN/
OUT
Function
Pin
Signal
IN/
OUT
Function
1
COMOUT1
-
Output signal common (DO0 to
DO15)
31
COMIN0
-
Input signal common (all inputs
except TRIG)
2
NC
*1
-
32
COMIN1
-
Input signal common (TRIG)
3
D0
OUT
Data output
33
TRIG
IN
Measurement trigger input
4
D1
OUT
Data output
34
NC
*1
-
5
D2
OUT
Data output
35
NC
*1
-
6
D3
OUT
Data output
36
RESET
IN
Reset input
7
D4
OUT
Data output
37
IN0
IN
Command input
8
D5
OUT
Data output
38
IN1
IN
Command input
9
D6
OUT
Data output
39
IN2
IN
Command input
10
D7
OUT
Data output
40
IN3
IN
Command input
11
D8
OUT
Data output
41
IN4
IN
Command input
12
D9
OUT
Data output
42
IN5
IN
Command input
13
D10
OUT
Data output
43
IN6
IN
Command input
14
D11
OUT
Data output
44
IN7
IN
Command input
15
D12
OUT
Data output
45
NC
*1
-
16
D13
OUT
Data output
46
NC
*1
-
17
D14
OUT
Data output
47
DSA
IN
Data send request signal
18
D15
OUT
Data output
48
NC
*1
-
19
NC
*1
-
49
NC
*1
-
20
NC
*1
-
50
NC
*1
-
21
NC
*1
-
51
NC
*1
-
22
NC
*1
-
52
ACK
OUT
Command execution completed
flag
23
NC
*1
-
53
RUN
OUT
ON during measurement mode
24
NC
*1
-
54
BUSY
OUT
ON during process execution
25
NC
*1
-
55
OR
OUT
Overall judgement result
26
NC
*1
-
56
ERROR
OUT
ON during error
27
NC
*1
-
57
STGOUT
OUT
Strobe trigger output
*2, *3
28
NC
*1
-
58
SHTOUT
OUT
Shutter trigger output
*4
29
NC
*1
-
59
GATE
OUT
ON during the set output time.
30
NC
*1
-
60
COMOUT0
-
Output signal common (ACK,
RUN, BUSY, OR, ERROR,
STGOUT, SHTOUT, and GATE)
Trigger inp
u
t (TRIG)
Sh
u
tter time
Imaging element
sh
u
tter signal
SHTOUT
10 ms
Trigger delay
O
N
OFF
O
N
OFF
O
N
OFF
The SHTOUT signal t
u
rns O
N
for approximately 10 ms (fixed)
w
hen the sh
u
tter time (expos
u
re period) elapses after
the trigger is inp
u
t from an external de
v
ice.
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......