Controlling Operation and Outputting Data with TCP No-protocol Communications
360
FQ2 User’s Manual
Command Details
Measurement Control and Measurement Acquisition Commands
●
MEASURE or M
Execute Measurement
This command executes one measurement.
If data output is not set, only the measurement is performed.
If data output is set, the measurement is performed and the result is returned as response data.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Measurement result
The measurement result is output as the response when data output is set.
The measurement result is not output when data output is not set.
Setting the Data To Output Automatically after Measurements: p. 352
A
S
M
E
CR
U
R
E
Delimiter
CR
M
Delimiter
or
CR
Meas
u
rement
res
u
lt
CR
O
K
Delimiter
CR
E
R
Delimiter
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......