PLC Link Connections
FQ2 User’s Manual
329
C
onne
cti
ng th
rough
Ethern
et
9
Changes to settings are not applied until the Vision Sensor is restarted. Therefore, save the settings and then restart
the Vision Sensor.
5-5 Saving Data to the Sensor p. 178
Setting the Data To Output Automatically after Measurements
You can set in advance the data to output automatically after measurements. (You can set up to 32 data items.)
Data That Can Be Output
You can output up to 32 data items (data 0 to data 31). The measurement data from inspection items that can
be output and the calculation results from the expression settings can be output. For data that can be output,
refer to the Measurement Data That Can Be Used for External Outputs and Calculations for each inspection
item.
Assigning Inspection Results to Output Data
You can individually assign the parameters of the inspection items to output data (data 0 to data 31).
The following procedure shows how to assign the measured position X of [0. Search] to data 0 for a binary
output.
[In/Out]
−
[I/O setting]
−
[Output data setting]
−
[Link data output]
−
[Output data set]
1
Press [0. Data 0].
2
Press [Data setting].
3
Press [I0. Search].
4
Press [Position X X].
5
If the inspection item allows multi-point output,
press the number ([0] to [30]) of the inspection result
for which to output the data from the list of inspec-
tion results.
To register something to data 1 and higher, repeat
this process.
The settings will be enabled after you restart the Sen-
sor.
Important
▲
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......