Performing Continuous Measurements
Continuous measurements are performed while the continuous measurement command is input from an
external device.
Setting Output Data
You can set the data to output after measurements.
Output Data
You can output any of the following data through the Parallel Interface Sensor Data Unit.
Outputting the Overall Judgement Result (OR Signal)
When the results of the inspection items are judged, if even one individual judgement result is NG, the OR
output signal is turned ON.
Data
Output contents
Signal used to output the data
OR signal
Overall judgement result
The results is output with the OR signal.
Parallel judgement
output
Judgement results of the judgement conditions
that are set for parallel output
The results are assigned to and output with
D0 to D15.
Parallel data output
Measurement values for inspection items and
results from expressions
The data is output as 16-bit data on D0 to
D15.
• You can also turn ON the overall judgement result output signal when all individual judgement results are OK.
Changing the Judgement Output ON Conditions: p. 244
• You can select whether to use the judgement result of one of the calculations (0 through 31) as the overall judge-
ment.
Using Calculation Results without Applying Them to the Overall Judgement: p. 161
• You can adjust the timing for outputting the OR signal and the ON time after judgement processing.
Adjusting the Judgement Output Timing: p. 242
PLC
(2) Performs contin
u
o
u
s
meas
u
rements
Or other
de
v
ice
(1) I
N
7 signal O
N
(I
N
0 to I
N
6 are OFF)
Note
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......