Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
384
FQ2 User’s Manual
Changing the Scene Number: 280F 00301000
This command changes the scene number to use.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Scene number (4 bytes)
28
0F
00301000
Scene number to change to (2
digits max.)
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
End code
00301000
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Scene number
Specifies the scene number (0 to 31) to change to.
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......