Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
FQ2 User’s Manual
241
8
Co
ntro
llin
g Operatio
n an
d Ou
tp
utti
ng Da
ta
with a Parall
el Con
nection
Getting Individual Judgements and Expression Judgements
Up to three judgement results of individual inspection items (item judgement signals OR0 to OR31) and
expression judgements (expression 0 judgement to expression 31 judgement) can be assigned to terminals
OUT0 to OUT2 and output to external devices.
Wiring
Example: Signals are assigned to terminals OUT0 to OUT2 as shown below.
• OUT0: Item 2 judgement (OR2)
• OUT1: Item 5 judgement (OR5)
• OUT2: Item 14 judgement (OR14)
As described above, if terminals OUT0 to OUT2 are all assigned to individual judgement output signals, the
BUSY signal and ERROR signal assigned as the default settings will no longer be output.
The timing for updating the OR signal and the ON time after judgement processing can be adjusted.
Adjusting the judgement output timing: p. 242
Output terminal
Default assignment
Output signals that can be assigned
OUT0
OR (Total judgement)
• Control signals: OR, BUSY, ERROR, READY, and RUN
STG (strobe trigger)
• Item judgements: OR0 (Item 0 judgement) to OR31
(Item 31 judgement)
• Expression judgements: Expression 0 judgement to
expression 31 judgement
OUT1
BUSY
OUT2
ERROR
The timing for updating the OR0 to OR31 signals and the ON time after judgement processing can be
changed.
Adjusting the judgement output timing: p. 242
Color
Signal
Description
The signals shown at the left are used.
Refer to the following information for signal wiring.
Black
OUT0 (OR2)
Outputs the judgement for
OR2.
Orange
OUT1 (OR5)
Outputs the judgement for
OR5.
Light
blue
OUT2 (OR14)
Outputs the judgement for
OR14.
Note
Note
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......