Outputting Data and Controlling Operation through EtherNet/IP
FQ2 User’s Manual
307
C
onne
cti
ng th
rough
Ethern
et
9
• Response Area
• Output Area
●
Accessing Communications Areas by Specifying I/O Memory Addresses
AT specifications can be set for variables to individually specify the I/O memory addresses that are assigned in
the communications areas.
1
Setting Tag Sets (Network Configurator)
Specify the tag names in the PLC directly by using the I/O memory addresses that are assigned in the
communications areas. (Output tags are specified for the input connections to the Sensor and input tags
are specified for output connections to the PLC.)
Setting Examples
Output tag: D0
Input tag: D100
2
Setting Variables (Sysmac Studio)
Define variables with AT specifications to the I/O memory addresses that are assigned in the communi-
cations areas as shown below.
Setting Examples
Variable: a (AT specification: D0.0)
Variable: b (AT specification: D0.1)
Variable: c (AT specification: D0.15)
Variable: d (AT specification: D1.0)
3
Setting Connections
Set the connections as shown in the following table.
Signal name
Variable name
FLG
EIPInput.StatusFlag.F[0]
BUSY
EIPInput.StatusFlag.F[1]
READY
EIPInput.StatusFlag.F[2]
OR
EIPInput.StatusFlag.F[3]
RUN
EIPInput.StatusFlag.F[4]
ERR
EIPInput.StatusFlag.F[15]
GATE
EIPInput.StatusFlag.F[16]
Command code
EIPInput.CommandCodeEcho
Response code
EIPInput.ResposeCode
Response data
EIPInput.ResposeData
Signal name
Variable name
Output data 1
EIPInput.OutputData[0]
· · ·
Output data 8
EIPInput.OutputData[7]
Originator device (PLC) settings
Target device (Sensor) settings
Input tag set: D0
Output tag set: Input101
Output tag set: D100
Input tag set: Output100
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......