Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
388
FQ2 User’s Manual
Setting the Inspection Item Data: 280F 00501020
This command sets the parameters and measurement values of the specified inspection item.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Inspection item number (4 bytes) External reference
number (4 bytes)
Set value (4 bytes)
28
0F
00501020
Inspection item number from 00
to 1F (2 digits max.)
External reference
number
Set value (1,000
times the actual
value)
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
End code
00501020
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Inspection item number
Specifies the number of the inspection item to set.
External reference num-
ber
Specifies the external reference number.
12-2 External Reference Parameters: p. 430
Setting
Specifies the set value.
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......