PLC Link Connections
FQ2 User’s Manual
325
C
onne
cti
ng th
rough
Ethern
et
9
You must specify in advance the data to output after measurements. You must also specify in advance the
Output Area in I/O memory to store the data in the PLC. After a single measurement or continuous
measurements, the data is automatically stored in the Output Area of the PLC via Ethernet.
For PLC Link communications, the following three communications areas are set in the PLC to perform
communications.
You can set the area and address settings in the communications specifications of the Vision Sensor to assign
the above three communications areas in the I/O memory of the PLC.
• An FQ2 Sensor operates as a TCP server. Therefore, the TCP connection must be made from the PLC. Refer to the
manual for the PLC for TCP connection methods.
• The port number on the FQ2 Vision Sensor is always 9877.
Command/response
communications
1. Command area
This is the area to which you write control commands for the
Vision Sensor to execute.
2. Response area
This is the area to which the Vision Sensor writes the results of
control commands executed from the Command Area.
Data output after mea-
surements
3. Output area
This is the area to which the Vision Sensor writes output data for
measurements after an inspection is performed.
A PLC Link uses three link areas to perform communications: the Command Area, Response Area, and
Output Area. A PLC Link is not the same as the Serial PLC Link protocol used to connect PLCs together with
serial communications.
Command area
The follo
w
ing control commands are
w
ritten to the
V
ision Sensor.
●
Control signals
●
Command code
●
Command parameters
Response area
The exec
u
tion res
u
lts from the
V
ision Sensor are
w
ritten here.
PLC (master)
O
u
tp
u
t area
O
u
tp
u
t data from the
V
ision Sensor
is
w
ritten here.
V
ision Sensor (sla
v
e)
Command
Response
Meas
u
rement res
u
lts are
w
ritten to
the Response Area of the PLC.
●
V
ision Stat
u
s Flags
●
Command code
●
Response code
●
Response data
●
O
u
tp
u
t data 0 to 31
Exec
u
tion
After meas
u
rements
Meas
u
rement res
u
lts are
w
ritten to the
O
u
tp
u
t Area.
Command/
response
comm
u
ni-
cations
The control commands
w
ritten to the
Command Area are exec
u
ted.
Data o
u
tp
u
t
after
meas
u
re-
ments
Note
Important
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......