put OUT0
Used to assign output signals to OUT0,
OUT1, and OUT2.
OR (total judgement) (default), READY,
RUN, STG (strobe trigger), OR0 (item 0
judgement) to OR31 (item 31 judgement)
and expression 0 judgement to expres-
sion 31 judgement
System
OUT1
BUSY (default), READY, RUN, STG
(strobe trigger), OR0 (item 0 judgement)
to OR31 (item 31 judgement) and
expression 0 judgement to expression 31
judgement
System
OUT2
ERROR (default), READY, RUN, STG
(strobe trigger), OR0 (item 0 judgement)
to OR31 (item 31 judgement) and
expression 0 judgement to expression 31
judgement
System
OR output
You can set the output conditions for the
OR signal and for output signals to which
judgements are assigned.
OK: ON or NG: ON (default)
System
Output mode
You can set the output mode for the OR
signal and for output signals to which
judgements are assigned.
One-shot output, Level output (default)
System
Output delay
When one-shot output mode is selected,
this parameter sets the delay from when
measurement processing is completed
until when the OR signal turns ON.
0 to 1,000 ms (default: 0 ms)
System
Output time
When one-shot output mode is selected,
this parameter sets the time that the OR
signal is ON.
1 to 1,000 ms (default: 5 ms)
System
BUSY output
Specifies when to turn OFF the BUSY
signal after starting measurement pro-
cessing.
Measurement (default), Data logging,
Image logging, or Result display
System
OUT0 Polarity
You can change the polarity of the output
signals that are assigned to OUT0 to
OUT2 (regardless of what signal is
assigned to the output).
Positive (default), Negative
System
OUT1 Polarity
Positive (default), Negative
System
OUT2 Polarity
Positive (default), Negative
System
BUSY LED
You can change the BUSY indicator to a
RUN indicator.
BUSY (default), RUN
System
Output control
You can select the data output method.
(Only when the FQ-SDU1
@
is con-
nected.)
None (default), Handshaking, or Sync.
Output
System
Menu command
Description
Setting range
Data
Refer-
ence
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......