Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
FQ2 User’s Manual
245
8
Co
ntro
llin
g Operatio
n an
d Ou
tp
utti
ng Da
ta
with a Parall
el Con
nection
Adjusting the End Timing of the BUSY Signal
The end timing of the BUSY signal can be changed.
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Output] Tab Page
−
[BUSY output]
Do not disconnect the Ethernet cable between the Sensor and the Touch Finder if the Sensor and Touch Finder
are connected through an Ethernet switch and the BUSY output condition is set to [Data logging], [Image
logging], or [Result display].
The Sensor will wait for the Touch Finder to answer, and the results and measurement time will be affected.
To disconnect the Sensor and Touch Finder during measurements in the above situation, clear the selection of
the Sensor from the list of Sensors on the Touch Finder before you disconnect the cable.
Changing the Polarity of the Output Signals
You can change the polarity of the output signals that are assigned to OUT0 to OUT3 (regardless of what
signal is assigned to the output).
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Output]
−
[OUT0 Polarity], [OUT1 Polarity] or [OUT2
Polarity]
Item
Description
BUSY output
Measurement (default)
The BUSY signal turns OFF when the measurement is completed.
Data logging
The BUSY signal turns OFF when data logging is completed.
Image logging
The BUSY signal turns OFF when image logging is completed.
Result display
The BUSY signal turns OFF when the result display is completed.
Item
Description
OUT0 Polarity,
OUT1 Polarity, or
OUT2 Polarity
Positive (default)
The output signal that is assigned to OUT0 to OUT3 is turned ON when the Sen-
sor is executing a process.
Negative
The output signal that is assigned to OUT0 to OUT3 is turned ON when the Sen-
sor can receive the trigger.
Important
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......