Menu Tables
428
FQ2 User’s Manual
Run Mode
Menu command
Description
Setting range
Data
Refer-
ence
S
e
le
ct
displa
y Graphic
Displays the input image.
---
---
Gr Details
Displays the inspection item individual
judgement results and measurement val-
ues.
---
Statistical data
Displays the total number of measure-
ments and the total number of NG overall
judgements and the NG ratio from when
the power supply was turned ON.
---
All results/Region
Displays the inspection item individual
judgement results for all inspection
items.
---
Trend Monitor
Displays the individual judgement results
saved in the Sensor in a trend monitor.
---
Histogram
Displays the individual judgement results
saved in the Sensor in a histogram.
---
Model region
Changes to Setup Mode and changes
the output form for measurement values.
---
Insp. region
Changes to Setup Mode and changes
the parameters for judgement conditions.
---
Adjust judgement
(Except for statistical
data)
Adjusts judgement parameters without
stopping measurements.
---
---
Auto display (trend
monitor and histo-
gram only)
Automatically sets the display range
according to the measurement results.
OFF or ON (default)
---
Display range (trend
monitor and histo-
gram only)
Changes the display range of measure-
ment values.
-999,999,999 to 999,999,999
---
Number of data
(trend monitor only)
Changes the number of displayed mea-
surement values.
200, 400, or 1,000 (default: 200)
---
Number of data (his-
togram only)
Changes the number of displayed mea-
surement values (i.e., the vertical display
range of the histogram).
5 to 1,000
---
Clear results
(graphic or g
details list)
Clears the measurement results of the
inspection items.
---
---
---
Clear results
Clears the total results of the inspection
items.
---
---
---
Delete stats (total
data)
Clears the Statistical data.
---
---
---
L
oggi
ng Image logging
Starts and stops logging in external
memory.
ON: Start or OFF: Stop
---
Data logging
ON: Start or OFF: Stop
---
TF settings
The same as for Setup Mode. (This does not apply to the PC Tool.)
The resolution of the measurement image can be set on the PC Tool.
Sensor setting
Switches to Setup Mode.
---
---
S
e
ns
or
m
o
n
ito
r Multi sensor
Simultaneously displays the images for
multiple connected Sensors.
---
---
NG sensor
From multiple connected Sensors, dis-
plays the image of only the Sensors with
NG results.
---
---
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......