External Reference Parameters
FQ2 User’s Manual
455
Appe
ndi
ce
s
12
121
Model
region
Rotation
Setting/Acqui-
sition
0: No rotation 1: Rotation
0
---
---
122
Rotation angle upper
limit
Setting/Acqui-
sition
−
180 to 180
180
---
---
123
Rotation angle lower
limit
Setting/Acqui-
sition
−
180 to 180
−
180
---
---
134
Mea-
sure-
ment
condi-
tions
Sub-pixel
Setting/Acqui-
sition
0: No, 1: Yes
0
---
---
135
Candidate level
Setting/Acqui-
sition
0 to 100
70
---
---
136
Judge-
ment
condi-
tions
Judgement upper limit
for search coordinate X
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
137
Judgement lower limit
for search coordinate X
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
138
Judgement upper limit
for search coordinate Y
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
139
Judgement lower limit
for search coordinate Y
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
140
Judgement upper limit
for search angle
Setting/Acqui-
sition
−
180 to 180
180
---
Adjust judge-
ment
141
Judgement lower limit
for search angle
Setting/Acqui-
sition
−
180 to 180
−
180
---
Adjust judge-
ment
142
Judgement upper limit
for correlation
Setting/Acqui-
sition
0 to 100
100
---
Adjust judge-
ment
143
Judgement lower limit
for correlation
Setting/Acqui-
sition
0 to 100
60
---
Adjust judge-
ment
145
Density deviation upper
limit
Setting/Acqui-
sition
Color Cameras: 0 to 221
Monochrome Cameras: 0
to 127
Color Cam-
era: 221
Monochrome
Camera: 127
---
Adjust judge-
ment
146
Density deviation lower
limit
Setting/Acqui-
sition
Color Cameras: 0 to 221
Monochrome Cameras: 0
to 127
0
---
Adjust judge-
ment
147
NG sub-region upper
limit
Setting/Acqui-
sition
0 to 100
100
---
---
148
NG sub-region lower
limit
Setting/Acqui-
sition
0 to 100
0
---
---
153
Mea-
sure-
ment
condi-
tions
Plain inspection
Setting/Acqui-
sition
0: No, 1: Yes
0
---
---
169
Gain setting
Setting/Acqui-
sition
0: 3
×
3 sub-divisions, 1: 5
×
5
sub-divisions, 2: 9
×
9 sub-
divisions
1
---
---
310
Logging
condi-
tions
Data logging switch for
entire unit
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
311
Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
312
Data logging switch for
correlation
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
313
Data logging switch
for density deviation
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
1
---
---
External
refer-
ence
number
Category Data name
Setting/Acqui-
sition
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......