Inspecting with the Sensitive Search Inspection Item
116
FQ2 User’s Manual
Changing the Number Region Divisions
You can change the number of divisions of the registered model. The default setting is 5
×
5.
[Inspect]
−
[Inspection]
−
[Sensitive Search]
−
[Modify]
−
[Details] Tab Page
−
[Model
parameter]
−
[Sub-model number]
Inspecting Plain Regions
Density deviations are used to inspect sections that are set as plain regions during teaching.
[Inspect]
−
[Inspection]
−
[Sensitive Search]
−
[Modify]
−
[Details] Tab Page
−
[Model
parameter]
−
[Plain inspection]
Unstable Search Results
Inclined Measurement Objects
Adjust the [Angle range] parameter to increase the range in which a search is made for the model.
The Search inspection item judges whether an image is OK or NG according to the correlation with a
previously registered image pattern. For this reason, if the object is at an angle, the correlation is reduced and
the image may be judged as NG. To achieve an OK judgement for the same image pattern even when the
object is at an angle, the rotation range must be widened.
[Inspect]
−
[Inspection]
−
[Sensitive Search]
−
[Modify]
−
[Details] Tab Page
−
[Model parameter]
1
Set [Rotation] to [Yes].
2
Press [Angle range] and set the following range.
Correlation Is Inconsistent Due to Low Contrast
Adjust the brightness to improve the contrast of the mark.
Adjust the brightness: p. 61
Parameter
Setting
Description
Sub-model number
3
×
3, 5
×
5 (default), or 9
×
9
Sets the number of divisions of the registered model.
Parameter
Setting
Description
Plain inspection
Yes or No (default)
Enables or disables inspecting plain sections.
Parameter
Setting
Description
Angle range
Range:
−
180 to 180
Default: Lower limit:
−
180,
Upper limit: 180
A search is performed within the set angle range.
The larger the angle range, the longer the processing time.
If you change the angle range, perform teaching again.
Important
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......