External Reference Parameters
450
FQ2 User’s Manual
180
Judge-
ment
condi-
tions
Edge position X upper
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
181
Edge position X lower
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
182
Edge position Y upper
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
183
Edge position Y lower
limit 0
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
185
Edge position X upper
limit 1
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
186
Edge position X lower
limit 1
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
187
Edge position Y upper
limit 1
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
99,999.9999
---
Adjust judge-
ment
188
Edge position Y lower
limit 1
Setting/Acqui-
sition
−
99,999.9999 to
99,999.9999
−
99,999.9999 ---
Adjust judge-
ment
190
Edge angle upper limit
Setting/Acqui-
sition
−
180 to 180
180
---
Adjust judge-
ment
191
Edge angle lower limit
Setting/Acqui-
sition
−
180 to 180
−
180
---
Adjust judge-
ment
192
Theta position compen-
sation upper limit
Setting/Acqui-
sition
−
360 to 360
360
---
Adjust judge-
ment
193
Theta position compen-
sation lower limit
Setting/Acqui-
sition
−
360 to 360
−
360
---
Adjust judge-
ment
310
Logging
condi-
tions
Data logging switch for
entire unit
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
311
Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
312
Data logging switch
for position compensa-
tion TH
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
313
Data logging switch
for detected edge posi-
tion X0
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
314
Data logging switch
for detected edge posi-
tion Y0
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
315
Data logging switch
for detected edge posi-
tion X1
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
316
Data logging switch
for detected edge posi-
tion Y1
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
317
Data logging switch
for detected edge angle
Setting/Acqui-
sition
0: Data logging OFF,
1: Data logging ON
0
---
---
External
refer-
ence
number
Category Data name
Setting/Acqui-
sition
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
Содержание FQ2 Series
Страница 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Страница 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Страница 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Страница 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Страница 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Страница 392: ...Controlling Operation and Outputting Data with FINS TCP No protocol Commands 390 FQ2 User s Manual MEMO ...
Страница 398: ...Controlling Operation and Outputting Data with RS 232C No protocol Communications 396 FQ2 User s Manual ...
Страница 399: ...11 Troubleshooting Troubleshooting 11 1 Error Histories 398 11 2 Error Messages 400 11 3 Basic Troubleshooting 401 ...
Страница 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Страница 513: ...Index FQ2 User s Manual 511 Index 12 ...
Страница 515: ......