678
Auxiliary Area Allocations by Address
Appendix D
A280
A280.02 Pulse Output
0 Output
Amount Set
Flag
ON when the number of output
pulses for pulse output 0 has been
set with the PULS(886) instruction.
Cleared when operation starts or
stops.
OFF: No setting
ON: Setting made
---
---
Cleared
Refreshed
when the
PULS(886)
instruction
is exe-
cuted.
Refreshed
when pulse
output
stops.
---
A280.03 Pulse Output
0 Output
Completed
Flag
ON when the number of output
pulses set with the PULS(886) or
PLS2(887) instruction has been out-
put through pulse output 0.
Cleared when operation starts or
stops.
OFF: Output not completed.
ON: Output completed.
---
---
Cleared
Refreshed
at the start
or comple-
tion of
pulse out-
put in inde-
pendent
mode.
---
A280.04 Pulse Output
0 Output In-
progress Flag
ON when pulses are being output
from pulse output 0.
Cleared when operation starts or
stops.
OFF: Stopped
ON: Outputting pulses.
---
---
Cleared
Refreshed
when pulse
output
starts or
stops.
---
A280.05 Pulse Output
0 No-origin
Flag
ON when the origin has not been
determined for pulse output 0 and
goes OFF when the origin has been
determined.
Turned ON when power is turned
ON.
Turned ON when operation starts.
OFF: Origin established.
ON: Origin not established.
---
---
Cleared
Refreshed
each cycle
during the
oversee-
ing pro-
cesses.
---
A280.06 Pulse Output
0 At-origin
Flag
ON when the pulse output PV
matches the origin (0).
OFF: Not stopped at origin.
ON: Stopped at origin.
---
---
Cleared
Refreshed
each cycle
during the
oversee-
ing pro-
cesses.
---
A280.07 Pulse Output
0 Output
Stopped Error
Flag
ON when an error occurred while
outputting pulses in the pulse output
0 origin search function.
The Pulse Output 0 Output Stop
Error code will be written to A444.
OFF: No error
ON: Stop error occurred.
---
---
Cleared
Refreshed
when ori-
gin search
starts.
Refreshed
when a
pulse out-
put stop
error
occurs.
---
A281
A281.00 Pulse Output
1 Accel/Decel
Flag
This flag will be ON when pulses are
being output from pulse output 1
according to an ACC(888) or
PLS2(887) instruction and the output
frequency is being changed in steps
(accelerating or decelerating).
Cleared when operation starts or
stops.
OFF: Constant speed
ON: Accelerating or decelerating
---
---
Cleared
Refreshed
each cycle
during
oversee
process.
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Содержание CP1L CPU UNIT - 03-2009
Страница 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Страница 2: ......
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 70: ...36 Function Blocks Section 1 5...
Страница 584: ...550 Trouble Shooting Section 8 7...
Страница 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 630: ...596 Sample Application Section 9 12...
Страница 654: ...620 Troubleshooting Unit Errors Section 11 4...
Страница 662: ...628 Replacing User serviceable Parts Section 12 2...
Страница 668: ...634 Standard Models Appendix A...
Страница 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Страница 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Страница 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Страница 806: ...772 Index...
Страница 808: ...774 Revision History...