206
Pulse Outputs
Section 5-2
CPU Units with 20, 30, 40 or 60 I/O Points
Auxiliary Area Data Allocation
Address
Default setting
High-speed counter operation settings:
Origin
searches
Word
Bit
CPU Units
with 60 I/O
Points
CPU Units
with 40 I/O
Points
CPU Units
with 30 I/O
Points
CPU Units
with 20 I/O
Points
Single-phase
(increment pulse
input)
Two-phase
(differential phases
x4, up/down, or
pulse/direction)
Origin searches
enabled for
pulse outputs 0
and 1
CIO 0 00
Normal
input 0
Normal
input 0
Normal
input 0
Normal
input 0
Counter 0,
increment input
Counter 0, A phase,
up, or count input
---
01
Normal
input 1
Normal
input 1
Normal
input 1
Normal
input 1
Counter 1,
increment input
Counter 0, B phase,
down, or direction
input
---
02
Normal
input 2
Normal
input 2
Normal
input 2
Normal
input 2
Counter 2,
increment input
Counter 1, A phase,
up, or count input
---
03
Normal
input 3
Normal
input 3
Normal
input 3
Normal
input 3
Counter 3,
increment input
Counter 1, B phase,
down, or direction
input
---
04
Normal
input 4
Normal
input 4
Normal
input 4
Normal
input 4
Counter 0,
phase-Z reset input
Counter 0, phase-Z
reset input
---
05
Normal
input 5
Normal
input 5
Normal
input 5
Normal
input 5
Counter 1,
phase-Z reset input
Counter 1, phase-Z
reset input
---
06
Normal
input 6
Normal
input 6
Normal
input 6
Normal
input 6
Counter 2,
phase-Z reset input
---
Pulse output 0:
Origin input
signal
07
Normal
input 7
Normal
input 7
Normal
input 7
Normal
input 7
Counter 3,
phase-Z reset input
---
Pulse output 1:
Origin input
signal
08
Normal
input 8
Normal
input 8
Normal
input 8
Normal
input 8
---
---
---
09
Normal
input 9
Normal
input 9
Normal
input 9
Normal
input 9
---
---
---
10
Normal
input 10
Normal
input 10
Normal
input 10
Normal
input 10
---
---
Pulse output 0:
Origin proxim-
ity input signal
11
Normal
input 11
Normal
input 11
Normal
input 11
Normal
input 11
---
---
Pulse output 1:
Origin proxim-
ity input signal
CIO 1 00 to
05
Normal
input 12
to 17
Normal
input 12
to 17
Normal
input 12
to 17
---
---
---
---
06 to
11
Normal
input 18
to 23
Normal
input 18
to 23
---
---
---
---
---
CIO 2 00 to
11
Normal
input 24
to 35
---
---
---
---
---
---
Function
Pulse output number
0
1
Pulse output PV storage words
PV range: 8000 0000 to 7FFF FFFF hex
(
−
2,147,483,648 to 2,147,483,647)
Leftmost 4 digits
A277
A279
Rightmost 4 digits
A276
A278
Reset Bits
The pulse output PV will be cleared when this bit is
turned from OFF to ON.
0: Not cleared.
1: Clear PV.
A540.00
A541.00
Содержание CP1L CPU UNIT - 03-2009
Страница 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Страница 2: ......
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 70: ...36 Function Blocks Section 1 5...
Страница 584: ...550 Trouble Shooting Section 8 7...
Страница 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 630: ...596 Sample Application Section 9 12...
Страница 654: ...620 Troubleshooting Unit Errors Section 11 4...
Страница 662: ...628 Replacing User serviceable Parts Section 12 2...
Страница 668: ...634 Standard Models Appendix A...
Страница 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Страница 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Страница 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Страница 806: ...772 Index...
Страница 808: ...774 Revision History...