693
Auxiliary Area Allocations by Address
Appendix D
A406
All
PLC Setup
Error Location
When there is a setting error in the
PLC Setup, the location of that error
is written to A406 in 4-digit hexadeci-
mal.
The CPU Unit will continue operating
and the ERR/ALM indicator on the
front of the CPU Unit will flash.
(A406 will be cleared when the
cause of the error is eliminated.)
0000 to 01FF
hexadecimal
Cleared
Cleared
Refreshed
when error
occurs.
A402.10
A407
A407.00
to
A407.12
Too Many I/O
Points, Details
Always 0000 hex.
0000 hex
Cleared
Cleared
---
A401.11,
A407.13
to
A407.15
A407.13
to
A407.15
Too Many I/O
Points, Cause
The 3-digit binary value of these bits
indicates the cause of the Too Many
I/O Points Error.
Note
These bits will be cleared
when the error is cleared.
010: Too
many Expan-
sion Unit and
Expansion I/O
Unit words
011: Too
many Expan-
sion Units
and Expan-
sion I/O Units
Cleared
Cleared
Refreshed
when error
occurs.
---
A424
A424.00
to
A424.15
Error Option
Board Flags
The bit corresponding to the option
slot turns ON when an error occurs
in an Option Board (A315.13 will be
ON).
Bit 00: Option slot 1
Bit 01: Option slot 2
ON: Error
OFF: No error
Cleared
Cleared
---
A353.13
A436
A436.00
to
A436.02
CPM1A Unit
Error Flags
ON when an error occurs in a CP-
series Expansion Unit or Expansion
I/O Unit.
A436.00: 1st Unit
A436.10: 2nd Unit
A436.02: 3rd Unit
OFF: No error
ON: Error
Retained
Cleared
---
---
A437
All
Number of
Connected
CPM1A Units
Stores the number of Expansion
Units and Expansion I/O Units con-
nected as a hexadecimal number.
Note
This information is valid only
when a Too Many I/O Points
error has occurred. CP1W/
CPM1A-TS002 and CP1W/
CPM1A-TS102 are each
counted as two Units.
0000 to 0007
hex
Retained
Cleared
---
---
A438
All
Pulse Output
2 Stop Error
Code
If a Pulse Output Stop Error occurs
for pulse output 2, the error code is
stored.
---
Retained
Cleared
Refreshed
when ori-
gin search
starts.
Refreshed
when a
pulse out-
put stop
error
occurs.
---
A439
All
Pulse Output
3 Stop Error
Code
If a Pulse Output Stop Error occurs
for pulse output 3, the error code is
stored.
---
Retained
Cleared
Refreshed
when ori-
gin search
starts.
Refreshed
when a
pulse out-
put stop
error
occurs.
---
A440
All
Max. Interrupt
Task Process-
ing Time
Contains the Maximum Interrupt
Task Processing Time in units of
0.1 ms.
(This value is written after the inter-
rupt task with the max. processing
time is executed and cleared when
PLC operation begins.)
0000 to FFFF
hexadecimal
Cleared
Cleared
See Func-
tion col-
umn.
---
Address
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
flags, set-
tings
Words
Bits
Содержание CP1L CPU UNIT - 03-2009
Страница 1: ...Cat No W462 E1 06 CP1L CPU Unit SYSMAC CP Series CP1L L_0D_ CP1L M_0D_ OPERATION MANUAL...
Страница 2: ......
Страница 4: ...iv...
Страница 10: ...x...
Страница 22: ...xxii...
Страница 34: ...xxxiv Conformance to EC Directives 6...
Страница 70: ...36 Function Blocks Section 1 5...
Страница 584: ...550 Trouble Shooting Section 8 7...
Страница 627: ...593 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Страница 630: ...596 Sample Application Section 9 12...
Страница 654: ...620 Troubleshooting Unit Errors Section 11 4...
Страница 662: ...628 Replacing User serviceable Parts Section 12 2...
Страница 668: ...634 Standard Models Appendix A...
Страница 698: ...664 Auxiliary Area Allocations by Function Appendix C...
Страница 746: ...712 Auxiliary Area Allocations by Address Appendix D...
Страница 773: ...739 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 774: ...740 Connections to Serial Communications Option Boards Appendix F...
Страница 806: ...772 Index...
Страница 808: ...774 Revision History...