359
Memory Cassette Functions
Section 6-5
2.
Set IOM Hold Bit Status at Startup and Forced Status Hold Bit Status at
Startup to Clear (OFF).
3.
Set Read DM from flash memory to Read. (Only when DM initial values
have been saved as described above.)
!Caution
The CP1H CPU Units automatically back up the user program and parameter
data to flash memory when these are written to the CPU Unit. Also, the CX-
Programmer can be used to save all of the data in the DM Area to the flash
memory for use as initial values when the power supply is turned ON. Neither
of these functions saves the I/O memory data (including HR Area data,
counter PVs and Completion Flags, and DM Area data other than initial val-
ues). The HR Area data, counter PVs and Completion Flags, and DM Area
data other than initial values are held during power interruptions with a bat-
tery. If there is a battery error, the contents of these areas may not be accu-
rate after a power interruption. If HR Area data, counter PVs and Completion
Flags, and DM Area data other than initial values are used to control external
outputs, prevent inappropriate outputs from being made whenever the Battery
Error Flag (A402.04) is ON.
6-5
Memory Cassette Functions
6-5-1
Overview
CP1H CPU Units have Memory Cassette functions that enable data in the
CPU Unit to be stored on and read from a special CP1W-ME05M Memory
Cassette. These functions can be used for the following applications.
• Copying data to other CPU Units to produce duplicate devices.
• Backing up data in case the CPU Unit needs to be replaced due to any
malfunction.
• Writing and updating data when existing device versions are upgraded.
Memory Cassette
Specifications
Use the following Memory Cassette.
Data that Can be
Stored on a Memory
Cassette
The following data can be stored on a Memory Cassette.
Model
Specifications
CP1W-ME05M
• Memory size
512 Kwords
• Storage capacity The following CPU Unit data (for each Unit)
• User programs
• Parameters
• Comment memory
• Function Block (FB) sources
• DM initial values in the built-in flash memory
• DM in RAM
• Write method
Operations from the CX-Programmer
• Read method
Powering up with DIP switch pin SW2 set to
ON, or operations from the CX-Programmer
Data stored on Memory Cassette
Location in CPU Unit
User programs
Built-in RAM, built-in flash
memory (User Program Area)
Parameters
PLC Setup, CPU Bus Unit set-
tings, routing tables
Built-in RAM, built-in flash
memory (Parameter Area)
Содержание CP1H-CPU - 05-2006
Страница 1: ...OPERATION MANUAL CP1H CPU Unit SYSMAC CP Series CP1H X40D CP1H XA40D CP1H Y20DT D Cat No W450 E1 02...
Страница 2: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised May 2006...
Страница 3: ...iv...
Страница 11: ...xii TABLE OF CONTENTS...
Страница 15: ...xvi...
Страница 19: ...xx...
Страница 31: ...xxxii Conformance to EC Directives 6...
Страница 71: ...40 Function Blocks Section 1 5...
Страница 133: ...102 Computing the Cycle Time Section 2 7...
Страница 169: ...138 CPM1A Expansion I O Unit Wiring Section 3 6...
Страница 411: ...380 Clock Section 6 8...
Страница 519: ...488 Replacing User serviceable Parts Section 10 2...
Страница 527: ...496 Standard Models Appendix A...
Страница 535: ...504 Dimensions Diagrams Appendix B...
Страница 628: ...597 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 629: ...598 Connections to Serial Communications Option Boards Appendix F...
Страница 659: ...628 PLC Setup Appendix G...
Страница 665: ...634 Index work words 159 write protection 370...
Страница 667: ...636 Revision History...