564
Auxiliary Area Allocations by Address
Appendix D
A738 to
A740
All
Power ON
Clock Data 7
These words contain the time at which
the power was turned ON seven times
before the startup time stored in words
A510 to A511.
A738.00 to A738.07: Seconds (00 to 59)
A738.08 to A738.15: Minutes (00 to 59)
A739.00 to A739.07: Hour (00 to 23)
A739.08 to A739.15: Day of month (00
to 31)
A740.00 to A740.07: Month (01 to 12)
A740.08 to A740.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A741 to
A743
All
Power ON
Clock Data 8
These words contain the time at which
the power was turned ON eight times
before the startup time stored in words
A510 to A511.
A741.00 to A741.07: Seconds (00 to 59)
A741.08 to A741.15: Minutes (00 to 59)
A742.00 to A742.07: Hour (00 to 23)
A742.08 to A742.15: Day of month (00
to 31)
A743.00 to A743.07: Month (01 to 12)
A743.08 to A743.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A744 to
A746
All
Power ON
Clock Data 9
These words contain the time at which
the power was turned ON nine times
before the startup time stored in words
A510 to A511.
A744.00 to A744.07: Seconds (00 to 59)
A744.08 to A744.15: Minutes (00 to 59)
A745.00 to A745.07: Hour (00 to 23)
A745.08 to A745.15: Day of month (00
to 31)
A746.00 to A746.07: Month (01 to 12)
A746.08 to A746.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A747 to
A749
All
Power ON
Clock Data
10
These words contain the time at which
the power was turned ON ten times
before the startup time stored in words
A510 to A511.
A747.00 to A747.07: Seconds (00 to 59)
A747.08 to A747.15: Minutes (00 to 59)
A748.00 to A748.07: Hour (00 to 23)
A748.08 to A748.15: Day of month (00
to 31)
A749.00 to A749.07: Month (01 to 12)
A749.08 to A749.15: Year (00 to 99)
See at left.
Retained Retained Written
when
power is
turned
ON.
A751
A751.11 DM Initial
Values Read
Error Flag
ON when an error occurred in transfer-
ring DM initial values from the DM initial
value area in flash memory to the DM
Area.
OFF: Normal
ON: Error
(failed to load)
Retained Cleared
---
---
A751.12 DM Initial
Values Save
Execution
Error Flag
ON when the DM Initial Values Transfer
Password (A752) is incorrect or when
the DM Initial values area was not spec-
ified when starting to transfer DM initial
values from the DM Area to the DM ini-
tial value area in flash memory.
OFF: Normal
ON: Error
(failed to save)
Retained Cleared
---
---
A751.13 DM Initial
Values Save
Error Flag
ON when an error occurred in transfer-
ring DM initial values from the DM Area
to the DM initial value area in flash
memory.
OFF: Normal
ON: Error
(failed to save)
Retained Cleared
---
---
A751.14 DM Initial
Values Save
Flag
ON while DM initial values are being
transferred from the DM Area to the DM
initial value area in flash memory.
OFF when the transfer has been com-
pleted.
OFF: Not being
saved
ON: Being
saved
Retained Cleared
---
---
A751.15 DM Initial
Values Save
Start Bit
Turn ON this bit to start transferring DM
initial values. This bit is valid only when
a correct password is stored in A752
and the DM Area Initial Value Area is
specified (i.e., when A753.00 is ON).
The system will turn this bit OFF auto-
matically when the transfer has been
completed.
Turned ON:
Transfer
started
OFF: Not trans-
ferring
ON: Transfer-
ring
Retained Cleared
---
---
Addresses
Name
Function
Settings
Status
after
mode
change
Status
at star-
tup
Write
timing
Related
Flags,
Settings
Word
Bits
Содержание CP1H-CPU - 05-2006
Страница 1: ...OPERATION MANUAL CP1H CPU Unit SYSMAC CP Series CP1H X40D CP1H XA40D CP1H Y20DT D Cat No W450 E1 02...
Страница 2: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised May 2006...
Страница 3: ...iv...
Страница 11: ...xii TABLE OF CONTENTS...
Страница 15: ...xvi...
Страница 19: ...xx...
Страница 31: ...xxxii Conformance to EC Directives 6...
Страница 71: ...40 Function Blocks Section 1 5...
Страница 133: ...102 Computing the Cycle Time Section 2 7...
Страница 169: ...138 CPM1A Expansion I O Unit Wiring Section 3 6...
Страница 411: ...380 Clock Section 6 8...
Страница 519: ...488 Replacing User serviceable Parts Section 10 2...
Страница 527: ...496 Standard Models Appendix A...
Страница 535: ...504 Dimensions Diagrams Appendix B...
Страница 628: ...597 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 629: ...598 Connections to Serial Communications Option Boards Appendix F...
Страница 659: ...628 PLC Setup Appendix G...
Страница 665: ...634 Index work words 159 write protection 370...
Страница 667: ...636 Revision History...