USER GUIDE

DISTRIBUTION PLATE

EK-Quantum 

Reflection PC-O11D D5 PWM D-RGB

Содержание 3831109826140

Страница 1: ...USER GUIDE DISTRIBUTION PLATE EK Quantum Reflection PC O11D D5 PWM D RGB ...

Страница 2: ...ith the installation process The EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber O ring gaskets The use of corrosion inhibiting coolants is always recommended for any liquid cooling system EKWB recommends any of the EKCryofuel for worry free usage ...

Страница 3: ...REPARING THE 011D CHASSIS 5 INSTALLING THE DISTRIBUTION PLATE IN THE 011D 6 RECOMMENDED DISTRIBUTION PLATE CONFIGURATIONS 7 CONNECTING THE D RGB LED STRIP 9 CONNECTING THE PUMP 9 TESTING THE LOOP 10 SUPPORT AND SERVICE 11 SOCIAL MEDIA 11 ...

Страница 4: ... 4 BOX CONTENTS EK Quantum Reflection PC O11D D5 PWM D RGB M3 x 11 7991DIN 2 pcs M4 x 14 7991DIN 3 pcs Allen Key 2 5 mm 1 pc EK Loop Multi Allen Key Allen Key 2 mm 1 pc ...

Страница 5: ...nstalling the distribution plate carefully read the PC case manual STEP 1 Unscrew the factory provided screws and remove the top panel from the case STEP 2 STEP 2 Remove side and the front panel from the case STEP 1 Factory provided Screws ...

Страница 6: ...ntumReflectionPC O11DD5PWMD RGB distribution plate into the PC case and align the mounting holes STEP 1 STEP 2 Secure the distribution plate to the chassis with three 3 M4 x 14 DIN7991 and two 2 M3 x 11 DIN7991 screws as shown in the diagram STEP 2 M3 x 11 DIN7991 M4 x 14 DIN7991 ...

Страница 7: ... 8mm 9mm may be used to install all EK fittings do not use excessive force If one of the prescribed components will not be installed ie bottom radiator or GPU block then one IN and one OUT port must still be joined together in order for this distribution plate to function TOP RADIATOR OUTLET GPU INLET GPU OUTLET DRAIN TOP RADIATOR INLET CPU INLET CPU OUTLET BOTTOM RADIATOR OUTLET BOTTOM RADIATOR I...

Страница 8: ... 8 FILL exterior DRAIN exterior ...

Страница 9: ...PUMP The EK D5 PWM pump has two connectors 1 4 pin Molex It must be connected directly to your PSU at all times as it is used to power the pump 2 4 pin PWM fan It can be connected to your motherboard s CPU_ Fan or designated water pump header It can also be connected to a controller This cable is used to control and report the rotational speed of the pump If it s not connected the pump will run at...

Страница 10: ...nnect power to any of the other components Turn on the PSU and let the pump run continuously It is normal for the coolant level to drop during this process as air collects in the distribution plate Inspect all parts of the loop and in the eventuality that coolant leaks fix the issue and repeat the testing process Ensure that all hardware is dry before the system is powered on in order to prevent a...

Страница 11: ...or assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCIAL MEDIA ...