Parameter
Monitor display and monitor output signals
FR-A700 EC
6 - 329
You can select the decimal digits of the monitor (Pr. 268)
As the operation panel (FR-DU07) display is 4 digits long, the decimal places may vary at analog
input, etc. The decimal places can be hidden by selecting the decimal digits. In such a case, the
decimal digits can be selected by Pr. 268.
Pr. 268
Description
9999 (initial value)
No function
0
When 1 or 2 decimal places (0.1 increments or 0.01 increments) are monitored,
the decimal places are dropped and the monitor displays an integer value
(1 increments).
The monitor value of 0.99 or less is displayed as 0.
1
When 2 decimal places (0.01 increments) are monitored, the 0.01 decimal place
is dropped and the monitor displays the first decimal place (0.1 increments).
When the monitor display digit is originally in 1 increments, it is displayed
unchanged in 1 increments.
Tab. 6-96:
Selection of decimal digits
NOTE
The number of display digits on the cumulative energizing time (Pr. 52 = 20), actual opera-
tion time (Pr. 52 = 23), cumulative energizing power (Pr. 52 = 25) or cumulative saving
power monitor (Pr. 52 = 51) does not change.