Communication operation and setting
Parameter
6 - 448
6.23.5
Mitsubishi inverter protocol (computer link communication)
You can perform parameter setting, monitor, etc. from the PU connector or RS-485 terminals of
the inverter using the Mitsubishi inverter protocol (computer link communication).
Communication specifications
Item
Description
Related
Parameters
Communication protocol
Mitsubishi protocol (computer link)
Pr. 551
Conforming standard
EIA-485 (RS-485)
—
Number of inverters connected
1 : N (maximum 32 units), setting is 0 to 31 stations
Pr. 117
Pr. 331
Communication
speed
PU connector
Selected from among 4800/9600/19200 and 38400bps
Pr. 118
RS-485 terminal
Can be selected from 300, 600, 1200, 2400, 4800, 9600,
19200 and 38400bps
Pr. 332
Control protocol
Asynchronous system
—
Communication method
Half-duplex system
—
Communication
specifications
Character
system
ASCII (7 bits or 8 bits can be selected)
Pr. 119
Pr. 333
Start bit
1 bit
—
Stop bit length
1 bit or 2 bits can be selected
Pr. 119
Pr. 333
Parity check
Check (even, odd) or no check can be selected
Pr. 120
Pr. 334
Error check
Sum code check
—
Terminator
CR/LF (presence or absence can be selected)
Pr. 124
Pr. 341
Waiting time setting
Selectable between presence and absence
Pr. 123
Pr. 337
Tab. 6-133:
Communication specifications
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......