Motor brake and stop operation
Parameter
6 - 250
DC feeding mode 1 (Pr. 30 = 10 or 11)
●
Setting "10, 11" in Pr. 30 enables DC power supply operation.
●
Leave the AC power supply connection terminal R/L1, S/L2, and T/L3 open and connect the
DC power supply to terminal P/+ and N/-. Also, remove jumpers across terminal R/L1-R1/
L11 and S/L2-S1/L21, and connect terminals R1/L11 and S1/L21 to terminal P/+ and N/-.
The diagram below is a connection example.
I001561E
Abb. 6-99:
Connection example for DC feeding mode 1
DC power
Inverter
M
3~
Forward rotation start
Reverse rotation start
Frequency command
Frequency setting
potentiometer
1 k
Ω,
1/2 W,
Inrush
current limit
circuit