Frequency/torque setting by analog input (terminals 1, 2 and 4)
Parameter
6 - 370
Pr. 868
V/f Control,
Advanced Magnetic
Flux Vector Control
Real Sensorless Vector Control, Vector Control Vektorregelung
Speed control
Torque control
Position control
0
(Initial
value)
Frequency setting
auxiliary
Speed setting auxiliary
Speed setting auxiliary
—
1
—
Magnetic flux command Magnetic flux command Magnetic flux command
2
—
Regenerative torque
limit (Pr. 810 = 1)
—
Regenerative torque
limit (Pr. 810 = 1)
3
—
—
Torque command
(Pr. 804 = 0)
—
4
Stall prevention opera-
tion level input
(Pr. 810 = 1)
Torque limit
(Pr. 810 = 1)
Torque command
(Pr. 804 = 0)
Torque limit
(Pr. 810 = 1)
5
—
—
Forward/reverse rota-
tion speed limit
(Pr. 807 = 2)
—
6
—
Torque bias input
(Pr. 840 = 1, 2, 3)
—
—
9999
—
—
—
—
Tab. 6-103:
Function of terminal 1 according to the control mode
Pr. 858
V/f Control,
Advanced Magnetic
Flux Vector Control
Real Sensorless Vector Control, Vector Control Vektorregelung
Speed control
Torque control
Position control
0
(Initial
value)
Frequency command
(AU signal-ON)
Speed command
(AU signal-ON)
Speed limit
(AU signal-ON)
—
1
—
Magnetic flux command Magnetic flux command Magnetic flux command
4
Stall prevention opera-
tion level input
(Pr. 810 = 1)
Torque limit
(Pr. 810 = 1)
—
Torque limit
(Pr. 810 = 1)
9999
—
—
—
—
Tab. 6-104:
Function of terminal 4 according to the control mode
NOTES
When "4" is set in both Pr. 868 and Pr. 858, terminal 1 is made valid and terminal 4 has no
function
When "4" (stall prevention/torque limit) is set in Pr. 868, functions of terminal 4 become valid
independently of whether the AU terminal is on or off.
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......