Simple mode parameter list
Basic settings
5 - 12
5.1.6
Operation mode (Pr. 79)
Select the operation command location and frequency command location.
For the terminal used for the X12 signal (PU operation interlock signal) input, assign "12" in
Pr. 178 to Pr. 189 "input terminal function selection" to assign functions. For Pr. 178 to
Pr. 189, refer to section 6.14.1. When the X12 signal is not assigned, function of the MRS
signal switches from MRS (output stop) to PU operation interlock signal.
Pr.
No.
Name
Initial
Value
Setting
Range
Description
LED Indication
79
Operation
mode
selection
0
0
External/PU switch over mode
Press the PU/EXT key to switch between the PU and
external operation mode. (Refer to section 5.2.)
At power on, the inverter is in the external operation
mode.
1
PU operation mode
2
Fixed to external operation mode
Operation can be performed by switching between the
external and Net operation mode.
3
External/PU combined operation mode 1
Running frequency
Start signal
PU (FR-DU07/FR-PU04)
setting or external signal
input (multi-speed set-
ting, across terminals 4-5
(valid when AU signal
turns on)).
External signal input
(terminal STF-, STR)
4
External/PU combined operation mode 2
Running frequency
Start signal
External signal input (Ter-
minal 2, 4, 1, JOG, multi-
speed selection, etc.)
Input from the PU
(FWD/REV keys)
6
Switch-over mode
Switch among PU operation, external operation, and
NET operation while keeping the same operation sta-
tus.
7
External operation mode (PU operation interlock)
X12 signal ON
:
Operation mode can be switched to the PU operation
mode.
(output stop during external operation)
X12 signal OFF
:
Operation mode can not be switched to the PU opera-
tion mode.
: OFF
: ON
External operation mode
PU operation mode
External operation mode
NET operation mode
External operation mode
NET operation mode
PU operation mode
External operation mode
PU operation mode
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......