Position control by vector control
Parameter
6 - 128
Setting procedure
Fig. 6-37:
Selection of position control
Set the motor and encoder.
(Pr. 71, Pr. 359, Pr. 369)
Set the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81) (Refer to section 6.2.2).
Test run
Set the motor capacity (kW) in Pr. 80 "Motor capacity" and set the
number of motor poles (number of poles) in Pr. 81 "Number of motor
poles". (V/f control is performed when the setting is "9999" (initial
value).)
앫
Set the electronic gear as required. (Refer to section 6.5.4.)
앫
Setting of positioning adjustment parameter as required. (Refer to section 6.5.5.)
앫
Gain adjustment of position control. (Refer to section 6.5.6.)
Perform secure wiring.
Select a control method. (Refer to section 6.2.2).
Make speed control valid by selecting "3" (position control) "4" (speed-
position switchover) or "5" (position-torque switchover) for Pr. 800.
Mount the FR-A7AP.
Set Pr. 71 "Applied motor", Pr. 359 "Encoder rotation direction" and
Pr. 369 "Number of encoder pulses" according to the motor and
encoder used. (Refer to page 3-41.)
Selection of position command source.
(Pr. 419)
Setting of parameter for position feed
(Pr. 465 to Pr. 494). (Refer to section 6.5.2.)
Position command by contact input
Set "0" (initial value) in Pr. 419.
Position command by inverter pulse
train input Set "2" in Pr. 419.
Selection of command pulse form.
(Pr. 428) (Refer to section 6.5.3.)
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......