Parameter overview
Parameter
6 - 64
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter
copy
Para-
meter
clear
All
para-
meter
clear
Refer
to
page
Re
la
te
d
parameters
✔
: enabled
—: disabled
Adjustment of analog input torque
magnetic flux comm
and (calibration)
C38
(932)
Terminal 4 bias com-
mand (torque/mag-
netic flux)
0.1%
0%
0–400%
Set the torque/magnetic flux com-
mand value on the bias side of ter-
minal 4 input.
(valid when Pr. 858 = 1, 4)
✔
—
✔
C39
(932)
Terminal 4 bias
(torque/magnetic flux)
0.1%
20%
0–300%
Set the converted % of the bias
side current (voltage) of terminal 4
input. (valid when Pr. 858 = 1, 4)
✔
—
✔
C40
(933)
Terminal 4 gain com-
mand (torque/mag-
netic flux)
0.1%
150%
0–400%
Set the torque/magnetic flux com-
mand value on the bias side of ter-
minal 4 input.
(valid when Pr. 858 = 1, 4)
✔
—
✔
C41
(933)
Terminal 4 gain
(torque/magnetic flux)
0.1%
100%
0–300%
Set the converted % of the gain
side current (voltage) of terminal 4
input. (valid when Pr. 858 = 1, 4)
✔
—
✔
—
989
Parameter copy alarm
release
1
10/100 *
10/100
Parameters for alarm release at
parameter copy
*
The setting depends on the
inverter capacity:
(01800 or less/02160 or more)
✔
—
✔
—
Buzzer control of
the operation panel
990
PU buzzer control
1
1
0
Without buzzer
✔
✔
✔
1
With buzzer
PU contrast
adjustment
991
PU contrast adjust-
ment
1
58
0–63
Contrast adjustment of the LCD of
the parameter unit (FR-PU04/FR-
PU07) can be performed.
0 (light)
→
63 (dark)
✔
—
✔
Parameter clear
, parameter copy
Pr.CL
Parameter clear
1
0
0/1
Setting "1" returns all parameters except calibration param-
eters to the initial values.
ALLC
All parameter clear
1
0
0/1
Setting "1" returns all parameters to the initial values.
Er.CL
Alarm history clear
1
0
0/1
Setting "1" will clear eight past alarms.
PCPY
Parameter copy
1
0
0
Cancel
0
1
Read the source parameters to the operation panel.
0
2
Write the parameters copied to the operation panel to the
destination inverter.
0
3
Verify parameters in the inverter and operation panel.
Tab. 6-1:
Parameter overview (64)
NOTE
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/
FR-PU07).
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......