Parameter
Communication operation and setting
FR-A700 EC
6 - 479
Modbus registers
●
System environment variable
The communication parameter values are not cleared.
For write, set the data as a control input instruction. For read, data is read as an inverter
operating status.
For write, set data as the operation mode setting. For read, data is read as the operation
mode status.
Register
Definition
Read/write
Remarks
40002
Inverter reset
Write
Any value can be written
40003
Parameter clear
Write
Set H965A as a written value.
40004
All parameter clear
Write
Set H99AA as a written value.
40006
Parameter clear
Write
Set H5A96 as a written value.
40007
All parameter clear
Write
Set HAA99 as a written value.
40009
Inverter status/control input instruction
Read/write
Refer to Tab. 6-161
40010
Operation mode/inverter setting
Read/write
Refer to Tab. 6-162
40014
Running frequency (RAM value)
Read/write
According to the Pr. 37 and
Pr. 144 settings, the frequency
and selectable speed are in
1r/min increments.
40015
Running frequency (EEPROM value)
Write
Tab. 6-160:
System environment variable