Parameter
Control mode
FR-A700 EC
6 - 73
Switching the control method from the external terminal (MC signal)
●
When "12 (2)" is set in Pr. 800 (Pr. 451 ), speed control is selected when the control mode
switching signal (MC) is off, and torque control is selected when the signal is off under real
sensorless vector control and vector control. Switching between speed control and torque
control is always enabled.
Under vector control, speed control/position control switchover and torque control/position
control switchover can be made by setting "4, 5" in Pr. 800. For the terminal used for MC
signal input, set "26" in any of Pr. 178 to Pr. 189 "Input terminal function selection" to assign
the function.
●
When an analog input terminal (terminal 1,4) is used for torque limit, torque command, etc.,
terminal functions also switch as below if control mode is switched.
Terminal 1 function according to control
Pr. 868
Real Sensorless Vector Control (Pr. 800 = 12), Vector Control (Pr. 800 = 2)
Speed control (MC signal-OFF)
Torque control (MC signal-ON)
0 (initial value)
Speed setting auxiliary
Speed limit auxiliary
1
Magnetic flux command
Magnetic flux command
2
Regenerative torque limit (Pr. 810 = 1)
—
3
—
Torque command (Pr. 804 = 0)
4
Torque limit (Pr. 810 = 1)
Torque command (Pr. 804 = 0)
5
—
Forward reverse speed limit (Pr. 807 = 2)
6
—
—
9999
—
—
Tab. 6-4:
Terminal 1 function when Pr. 800 = 12 or 2
Pr. 868
Vector Control (Pr. 800 = 4)
Speed control (MC signal-OFF)
Position control (MC signal-ON)
0 (initial value)
Speed setting auxiliary
—
1
Magnetic flux command
Magnetic flux command
2
Regenerative torque limit (Pr. 810 = 1)
Regenerative torque limit (Pr. 810 = 1)
3
—
—
4
Torque limit (Pr. 810 = 1)
Torque limit (Pr. 810 = 1)
5
—
—
6
Torque bias
—
9999
—
—
Tab. 6-5:
Terminal 1 function when Pr. 800 = 4
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......