Pyramix Monitor Section
9 - 64
Ramses MSC reference guide
Pyramix Monitor Section : Monitor ! page
In Place/Center
: In
Solo
and
SoloX
, toggles between
In Place
and
Center
.
Center
routes the soloed
channel(s) to the Center speaker or equally to the L/R speakers if no center speaker is present.
In Place
mode is the normal Solo, SoloX mode.
Output
, right-hand area
Monitor Level box
Displays the current output level. Output level can be entered numerically in the box
after clicking on it.
Volume Knob:
sets all the output gains in a range from -144.5dB to +24dB. Double-click to set it to 0dB.
Note:
Maximum permissible volume can be set in the
Configure
page.
Mute:
button mute the outputs.
Dim:
button reduces the output level by an amount set in the
Configure
page. Default value is -20dB.
Below these buttons is the
Peak Meter Selection:
Indicator/Button. This indicates what the Peak Meter display below the button is
looking at. (The selection also affects External Metering if you are using it) Clicking on the button drops
down a list of sources that can be metered from a choice of
Master Output
I.e.Monitor Output,
Mixer
Buses
and any available
Externals
.
Speaker Sets
Speaker Sets are set-up in the
Configure
page.
A speaker set consists of:
A
Patch
: This connects signals to the physical outputs of the board(s). The number of connection will
depend on the number of speakers you want to connect. Since the number of available live outputs
depends on the selected sampling rate, the patch will differ for 1Fs, 2 Fs, 4Fs and 8 Fs sampling rates.