Setup
Page 44
©
2017 Sensata Technologies
TECH: 02 Port Vers/ARTR=4.0
Displays version of all router-connected units and the port#s to which they are assigned (P1-6).
Info:
The router version displays on the top line of the screen of the TECH’s versions
menu item.
Info:
The
BMK, AGS, and the remote accessories may display a “
0.0
” version for several
reasons. Either the accessory is not installed, there is no communication because of a
bad or miswired network cable, the device is not powered, or the device is bad.
TECH: 03 AccPort Versions
The
AccPort Versions
menu displays the version of all inverter-connected accessories and the
port #s to which they are assigned (P1A-6A).
TECH: 04 PT-100 Versions
Displays the version# of each connected PT Controller.
TECH: 05 Fault History
This menu provides a two-screen display (only one screen display for AGS faults) of historic
information for each of the last 9 inverter and AGS fault records. Info for each fault displays
from the most recent fault (H1) to the previous/past faults (H2 up to H9). See Figure 3-19 for
examples of inverter fault history screens, Figure 3-20 for an example of an AGS fault history
screen, and Figure 3-21 for an example of PT fault history screens.
Note:
If no faults are on record, the display shows “ No Fault History”.
Info:
All recorded fault history records are retained, even if power is removed from the
router.
•
INV Faults
– Select to display a history of the last nine inverter faults.
•
AGS Faults
– Select to display a history of the last nine AGS faults.
•
PT Faults
– Select to display a history of the last nine PT faults.
•
Clear All Faults
– Select to clear all recorded fault history. Per directions on screen, press
and hold the SELECT knob for ~ 5 seconds until the screen displays “
All Fault History cleared
”.
You are then returned to the
05 Fault History
main menu.
01 INV Temperatures
BTS ---F Tfmer ---F
FETs ---F
P1 Read TECH
• 01D
AGS Sensor Temp
– Displays the temperature of the AGS’s Battery Temp Sensor (BTS)
that is connected to the battery bank.
• 01E
ACLD Temperature
– Displays the internal temperature of the ACLD.
• 01F
PT Temps
– Displays the temperature of each PT Controller’s Battery Temp Sensor
(BTS), main power transformer, and Field Effect Transistors.
To access the TECH button’s port-speci
fi
c menus:
1. From the System Home screen (press and hold METER button for approximately 3 secs to
access), press the PORT button.
2. Continue to press the PORT button until the port# with the connected inverter appears
(“INV Home” displays in the lower right corner of screen).
3. Press the TECH button. The
01 INV Temperatures
screen displays for the selected inverter.
Info:
The remaining TECH menus can also be accessed as port-speci
fi
c. However, these
menus are identical in function as when accessed as ALL ports TECH menus.
Figure 3-18, Port-Specifi c TECH Menus