2017 Sensata Technologies
Page 161
Appendix B – Compatibility Matrix
Button
FEATURES/SETTINGS
Model/
Level
Required
Default
Setting
Main
Menu
Menu
Heading/Item
Selections/
Adjustments Range
SETUP (Cont.)
07 PT
Setup
07A Battery Type
AGM1, AGM2, Flooded, GEL
≥
Level 1
Flooded
Custom
Absorb = 12.0-16.0V*
≥
Level 3
[2]
12.0V
Float = 12.0-16.0V*
13.2V
EQ Volts = 12.0-16.0V*
14.0V
EQ Time = 0.1-25.5Hrs
4.0 Hrs
CC/CV
Max Chg = 20-990A
≥
Level 4
200A
CV Chg = 12.0-16.0V*
13.8V
CV Chg Done Time,
Amps, Hold Volts
Time
CV Chg Done Time =
0.1-25.5 Hrs
2.0 Hrs
CC/CV Max Chg Time =
OFF, 0.1-25.5 Hrs
12.0 Hrs
VDC Recharge =
12.0-16.0V*
12.0V
CV Chg Done Amps =
0-250ADC
20 ADC
CC/CV Max Chg Time =
OFF, 0.1-25.5 Hrs
12.0 Hrs
VDC Recharge =
12.0-16.0V*
12.0V
Hold CV Charge Volts
07B Absorb Done
Time, Amps, SOC
Time
Time = 0.1-25.5 Hrs
≥
Level 4
[4]
2.0 Hrs
Amps = 0-250 ADC
≥
Level 4
20 ADC
SOC = 50-100%
≥
Level 4
[6]
100%
07C PT Max Charge
Rate = 0-100%
≥
Level 3
100%
Time = OFF, 0.1-25.5 Hrs
≥
Level 4
OFF
07D Bulk Start
Daily/SunUp = YES, NO
≥
Level 4
YES
Low VDC = 9.0-16.0*
10.0V
SOC = OFF, 50-100%
≥
Level 4
[6]
80%
07E PT Relay VDC
Engage VDC = 8.0-17.0*
≥
Level 4
10.0V
Engage Delay = 0-127s, 1-127m
10 Secs
Disengage VDC = 8.0-17.0*
14.0V
Disengage Delay = 0-127s, 1-127m
10 Secs
07F PT Relay SOC
Engage SOC = 20-100%
≥
Level 4
[6]
50%
Disengage SOC = 20-100%
100%
Содержание ME-ARTR
Страница 1: ...ME ARTR Advanced Router Owner s Manual Version 4 0 ...
Страница 181: ...NOTES ...