Using a BMK: Operation/Monitoring
Page 112
©
2017 Sensata Technologies
Figure 9-2, BMK SETUP Menu Maps
METER: 05H Maximum VDC
This menu displays the highest battery voltage since the last reset. The voltage shown is averaged
each second, and this allows you to check your charging system (e.g., battery charger, charge
controller, etc.,) to ensure the charging voltage has been attained. This is also helpful when
troubleshooting or detecting if an overcharge condition has occurred. To reset this display, press
and hold the rotary SELECT knob for ~2 seconds while the
Maximum VDC
display is shown. If the
battery monitor is not connected or not communicating, the display shows “
0.0
”.
METER: 05I Days Since 100%
This read-only menu displays the number of days since the battery was at 100% SOC, and is
calculated in the router.
Info:
This display resets either once the battery SOC reaches 100%, power to the
router is lost, or the data communications from the BMK is lost.
Info:
The
METER: 05I Days Since 100%
menu uses information from the
METER:05A
BMK SOC
menu to determine the last time the battery SOC was at 100%.
Info:
For the
METER: 05I Days Since 100%
to increment, an optional battery monitor
(ME-BMK/ME-BMK-NS) must be connected and the
METER: 05A BMK SOC
meter must
not display
100%
[must display a valid SOC value –
Think’n
,
No Comm
, or any BMK fault
(i.e.,
Factory Fault
,
Power-up Fault
, or
Unknown Fault ##
) are not valid SOC values].
Info:
The
METER: 05I Days Since 100%
menu is similar to the
04F Since 100% Days
menu (calculated in AGS). If an AGS is installed at a later date (or router is reconnected),
the two menus are not coordinated with each other. However, they will be automatically
synchronized once the BMK’s
METER: 05A BMK SOC
menu reaches 100% SOC (or you
can manually synchronize by momentarily removing the network cable from the BMK).
9.2.3
ME-ARTR Router’s BMK Menu Maps
Figures 9-2, 9-3 & 9-4 are a complete overview of the battery monitor settings and information
displays available from the ME-ARTR router’s SETUP and METER menus. Refer to Appendix A
in the back of this manual for a glossary of abbreviations that may appear on the router’s LCD
display.
05A Charge
Efficiency = Auto
P4 View BMK SETUP
BMK Home screen
P
Set Charge
Efficiency = Auto
P4 edit BMK SETUP
R
Auto, 50-99%
System Home screen
Battery Monitor
SOC:100% -103AHrs
27.22VDC -101.4ADC
P4 BMK Home
Inverting
SOC: 100% Gen Off
27.2VDC 101.4ADC
ALL System Home
OR
04 AGS Setup
05 BMK Setup
06 RC Setup
ALL Select SETUP
Set Battery AmpHrs
Size = 400 AHrs
P4 edit BMK SETUP
05B Battery AmpHrs
Size = 400 AHrs
P4 View BMK SETUP
P
200–2500 AH
SETUP
Press
P
R
Note:
The BMK must be connected and communicating with the ME-RTR for the
BMK displays to appear. If no BMK, then “NO BMK Present” displays.
Содержание ME-ARTR
Страница 1: ...ME ARTR Advanced Router Owner s Manual Version 4 0 ...
Страница 181: ...NOTES ...