2017 Sensata Technologies
Page 159
Appendix B – Compatibility Matrix
Button
FEATURES/SETTINGS
Model/
Level
Required
Default
Setting
Main
Menu
Menu
Heading/Item
Selections/
Adjustments Range
SETUP (Cont.)
03 Charger
Setup
(Cont.)
03C Battery Type
AGM1, AGM2, Flooded, GEL
≥
Level 1
Flooded
Custom
Absorb = 12.0-16.0V*
≥
Level 3
[2]
12.0V
Float = 12.0-16.0V*
13.2V
EQ Volts = 12.0-16.0V*
14.0V
EQ Time = 0.1-25.5Hrs
4.0 Hrs
CC/CV
Max Chg = 20-990A
≥
Level 4
200A
CV Chg = 12.0-16.0V*
13.8V
CV Chg Done Time,
Amps, Hold Volts
Time
CV Chg Done Time =
0.1-25.5 Hrs
2.0 Hrs
CC/CV Max Chg Time =
OFF, 0.1-25.5 Hrs
12.0 Hrs
VDC Recharge =
12.0-16.0V*
12.0V
CV Chg Done Amps =
0-250ADC
20 ADC
CC/CV Max Chg Time =
OFF, 0.1-25.5 Hrs
12.0 Hrs
VDC Recharge =
12.0-16.0V*
12.0V
Hold CV Charge Volts
03D Absorb Done
Time, Amps, SOC
Time
Time = 0.1-25.5 Hrs
≥
Level 4
[4]
2.0 Hrs
Amps = 0-250 ADC
≥
Level 4
20 ADC
SOC = 50-100%
≥
Level 4
[6]
100%
03E Max Charge
Rate = 0-100%
≥
Level 3
100%
Time = OFF, 0.1-25.5 Hrs
≥
Level 4
12.0 Hrs
03F Final Charge
Stage
Multi-Stage, Float, Silent
Multi-
Stage
Multi-Stage
≥
Level 1
Float
≥
Level 4
Silent VDC Rebulk = 12.0-16.0*
≥
Level 4
12.0V
03G
Always Start
Charge in Bulk
Enabled, Disabled
≥
Level 4
Disabled
04 AGS
Setup
04A Gen Run DC
Volts
OFF, Start Volts= 9.0-15.9*
≥
Level 1
11.5V
Start Delay= 0-127s, 1-127m
120 Secs
Stop Volts= 9.1-16.0*, Float
14.4V
Stop Delay= 0-127s, 1-127m
120 Secs
04B Gen Run Time
OFF, Start = 12:00AM-11:45PM
≥
Level 1
OFF
Stop Daily = 12:00AM-11:45PM
12:00AM