Using an AGS Module: Operation
Page 96
©
2017 Sensata Technologies
METER: 04C Gen Run Time Menu
This read-only menu displays the length of time the generator has been running since it was
autostarted by the AGS. This is useful when trying to determine how long the generator has
been running since it was autostarted—in case you were not present when it started. This menu
is enabled when the
CTRL: 03 Gen Control
menu is set to
AUTO
, but does not display run time
when the generator has been manually started. This meter is not designed to replace an hour
meter that shows the total hours the generator has run—refer to the
METER: 04G Gen Hour Meter
menu.
Info:
The
Gen Run Time
menu’s timer is started when the gen run sense voltage/signal
is correct and quali
fi
ed at the AGS module. It is not considered quali
fi
ed until after a full
start attempt and the
04I
Gen Warm-up Time
setting is satis
fi
ed. Cooldown and warm-
up times are not included in the gen run time display.
Total generator run time
=
Gen
Run Time
+
Gen Warm-up Time
+
Gen Cooldown Time
.
Info:
The times in this display are shown in tenths of an hour (e.g., 0.0 hrs., 0.1 hrs.,
etc.,)—thus, 0.1 hrs. = 6 minutes.
Info:
Depending on the ME-AGS-N version, the
Gen Run Time
display resets to 0.0
differently. The ME-AGS-N (Ver 5.2): Resets to 0.0 when the generator autostart has
fi
nished. The ME-AGS-N (
≥
Ver 5.3): Resets to 0.0 when another generator autostart is
triggered.
Info:
This display is used by the
SETUP: 04F Max Gen Run Time
menu to determine the
generator’s maximum run time when started automatically.
METER: 04D AGS Sensor Temp Menu
When the AGS remote temp sensor (included with AGS, but use is optional) is connected to the
AGS’s REMOTE (purple) port, this read-only menu displays the temperature of the temp sensor.
If the temperature around the sensor is a very high (>104F), the display will show “
TS Hot
”, and
if very cold (<33F), the display will show “
TS Cold
”. If the temperature sensor is not installed,
the display will show “
TS Open
”.
Info:
The temperature in the
METER: 04D AGS Temp
menu can be displayed in either
Fahrenheit (default) or Celsius depending on the
SETUP: 01D Temp Display
setting.
If an optional ME-PT1 (or ME-PT2) pigtail adapter is connected to the AGS’s REMOTE (purple)
port, and the
Set Gen Run Temp
(
Start Temp
) setting is set to
ExtInput
(under the
SETUP: 04E
Gen Run Temp
menu), this display will show “
Ext ON
” when the ME-PT1 has +12 present on its
input (or the ME-PT2 is closed); and, will show “
Ext OFF
” when the ME-PT1 does not have +12 on
its input (or the ME-PT2 is open).
METER: 04B DC Volts to AGS
This read-only menu displays the DC voltage measured at Terminal #3 and Terminal #4 of the AGS
module. This menu is useful in setting up the voltage start for the AGS, and for troubleshooting
its operation.
Info:
The DC voltage reading in the
04B DC Volts to AGS
(DC voltage to AGS) menu
may vary from the DC voltage readings in the METER button’s
01A DC Volts to Inv
(DC voltage to inverter) and
05B DC Volts – BMK
(DC voltage to BMK) menus. For
veri
fi
cation and testing purposes, read the appropriate related meter for each device.