Using a PT Controller: Operation/Monitoring
©
2017 Sensata Technologies
Page 137
Table 12-1, PT Default Settings on ME-ARTR
Menu Items
Default Settings
Battery Type
Flooded
Absorb Done
Time = 2.0 Hrs, Amps = 20 ADC, SOC = 100%
Max Charge Rate
Rate = 100%, Time = OFF
Bulk Start
Daily/SunUp = YES
Volts = 10.0 (12V), 20.0 (24V), 40.0 (48V)
SOC = 80%
PT Relay VDC
Engage VDC = 20V, Disengage VDC = 28V
Engage Delay = 10 secs, Disengage Delay = 10 secs
PT Relay SOC
Engage SOC = 50%
Disengage SOC = 100%
PT Alarm
ON Volts = 10.0 (12V), 20.0 (24V), 40.0 (48V)
ON Delay = 10 Sec
OFF Volts = 14.0 (12V), 28.0 (24V), 56.0 (48V)
OFF Delay = 10 Sec
Power Save PT
Display = 15 Min
Figure 12-4, PT Charge Controller CTRL Menu Map
CTRL
03 Gen Control
04 RTR Aux Relay
05 PT Control
ALL Select CTRL
05A PT Chg Ctrl x7
Multi-Stage
[Chg Mode]
SYS View PT CTRL
05B PT Aux Relay x7
DISENGAGED
C0# View PT CTRL
P
Multi-Stage
Charger Off
Start Float
Start Bulk
Start EQ
P
R
R
P
DISENGAGED
VDC
FAULT
ENGAGED
SOC**
R
05C PT Alarm Ctrl x7
OFF
C0# View PT CTRL
P
05D PT MPPT Ctrl x7
15 Min Sweep
C0# View PT CTRL
R
P
Set PT CHg Ctrl x7
EQ Charge Starts
In 5.0 seconds
SYS View PT CTRL
Set PT Chg Ctrl x7
EQ STARTED
SYS View PT CTRL
X5
secs
** - Requires a BMK. If BMK not
installed, will show “No BMK Present”.
EQ not allowed in
this battery type
SYS View PT CTRL
or
P
P
05B PT Aux Relay x7
DISENGAGED
C0# Select PT CTRL
P
05C PT Alarm Ctrl x7
OFF
C0# Select PT CTRL
5 Min Sweep
15 Min Sweep
1 Hour Sweep
Fixed Sweep
OFF
VDC
FAULT
ON
P
05D PT MPPT Ctrl x7
15 Min Sweep
C0# Select PT CTRL
P
Note:
C0#
(blinking) = Shows data for the PT controller
(per the assigned DIP switch number inside that PT) that
appears on the router’s display (lower left). Rotate the
SELECT knob to view/edit data for any additional connected
controller(s). If only one controller connected, “SYS” appears
in lower left for 05B, 05C, and 05D menu displays.
12.2.3
PT Charge Controller Menu Maps
Figures 12-4 through 12-8 are a complete overview of the PT settings and information displays
available from the ME-ARTR router’s CTRL, METER, and SETUP menus. Refer to Appendix A in the
back of this manual for a glossary of abbreviations that may appear on the router’s LCD display.
Note:
When applicable, battery voltage defaults and ranges are shown for a 12-volt battery
(24-volt systems multiply by 2; 48-volt systems multiply by 4).
Содержание ME-ARTR
Страница 1: ...ME ARTR Advanced Router Owner s Manual Version 4 0 ...
Страница 181: ...NOTES ...