Using an AGS Module: Troubleshooting
©
2017 Sensata Technologies
Page 105
8.3
ME-AGS-N Router Troubleshooting (with the ME-ARTR)
This section assists you in using your router to identify a fault, and to resolve an abnormal
operational condition detected within your AGS system.
8.3.1
AGS Fault Message Screens for the Router
When an AGS fault is detected, and the ARTR’s FAULT LED comes on, the fault status is displayed
on the LCD screen. Figure 8-5 is an example of how fault messages appear on the ME-ARTR. Use
the ARTR’s LCD screen and the information in this section to identify and correct the issue.
The FAULT LED lights solid red if the ARTR’s display is on the port/device with the active fault,
but
fl
ashes red if a different port/device has the active fault. Navigate to the port/device with the
active fault—the FAULT LED turns solid red when you are on the correct port/device.
Blinking (red)
FAULT LED
AGS Home Screen
FAULT
PWR
CHG
INV
Auto Gen Start
Fault Temp 0.0Hrs
25.2VDC 77F
P6 AGS Home
Port Screen
Device Menu
Heading
DC Volts
AGS
Device
Status
Device
Gen Run Time
Temperature
AGS Temp
Sensor
Solid (red)
FAULT LED
System Home Screen
System Status
FAULT
PWR
CHG
INV
Off
Fault Temp
25.2VDC -0.0ADC
ALL System Home
DC Volts
Device Menu
Heading
Accessory Status
DC Amps
Port Screen
Figure 8-5, ME-AGS-N Fault Message – Router Screens
blinking FAULT indication on the remote and a solid red STATUS indicator on the AGS controller).
• If using the temperature autostart feature in an RV coach, set the air conditioner thermostat
slightly less than the setting (
04E Gen Run Temp
menu). If using two A/C’s, it is suggested
that the second air conditioner thermostat be set 2° to 5° higher than the
fi
rst air conditioner.
• When the generator starts successfully, the STATUS indicator on the AGS controller will turn
solid green. The generator will run until an autostop condition is reached or until it is manually
turned off; at which time a stop signal will be sent to the generator.
• If the gen is running when the AGS’s TEST button is pressed, the gen will stop and then start
again. The generator will then run for approximately 30-60 seconds before shutting off.
• There is a delay before the AGS attempts to start the generator. The delay is adjustable on
volts and amps (
04A Gen Run DC
Volts
and
04C Gen Run AC Amps
settings). There is no delay
if the AGS attempts to start the generator when the temperature around the remote temp
sensor rises to the
04E Gen Run Temp
setting.
• Several autostart/autostop settings can be active at once. However, once an autostart condition
becomes active, all other autostart conditions are ignored until the speci
fi
c condition that caused
the generator to start (e.g.,
Start AC Amps
) is satis
fi
ed by its autostop condition (e.g.,
Stop AC
Amps
). Once the generator has completed this autostart/autostop cycle, the AGS immediately
begins to monitor for any active autostart/autostop settings again.