Operation
©
2017 Sensata Technologies
Page 59
FAULT
PWR
CHG
INV
Absorb Charging
Settings/Info...
Absorb Charging
appears on LCD. PWR (green) LED
is on solid. CHG (green) LED is typically on solid, but
may blink. FAULT (red) LED is off, and INV (green)
LED could be on or off.
Figure 5-10, Absorb Charging Mode
• Absorb
Charging
(Absorb)
– The Absorb Charge state is the constant voltage stage and
begins when the absorb voltage is reached (determined by the SETUP button’s
03C Battery Type
setting) while Bulk charging. During this stage, the DC charging current decreases in order to
maintain the absorb voltage setting. This charge stage continues until the
03D Absorb Done
(
Time
,
Amps
, or
SOC
) or
03E Max Charge: Time
setting is reached.
Charger Standby
appears on LCD. PWR (green) LED
is on solid and CHG (green) LED blinks. FAULT (red)
LED is off, and INV (green) LED could be on or off.
FAULT
PWR
CHG
INV
Bulk Charging
Settings/Info...
Bulk Charging
appears on LCD. PWR (green) LED
is on solid. CHG (green) LED is typically on solid, but
may blink. FAULT (red) LED is off. INV (green) LED
could be on or off.
• Bulk Charging (Bulk)
– The battery charger is delivering maximum current (determined
by the SETUP button’s
03E Max Charge: Rate
setting) to the batteries. The charger remains in
Bulk charge until the absorb voltage (determined by the SETUP button’s
03C Battery Type
menu
setting) or the
03E Max Charge: Time
setting is reached.
Figure 5-11, Bulk Charging Mode
FAULT
PWR
CHG
INV
Charger Standby
Settings/Info...
Figure 5-12, Charger Standby Mode
Charging
appears on LCD. PWR (green) and CHG
(green) LEDs are on solid. FAULT (red) LED is off, and
INV (green) LED could be on or off.
FAULT
PWR
CHG
INV
Charging
Settings/Info...
• Charging
(Charge)
– Once Charge mode is enabled, the unit waits and displays “
Charging
”
to determine the charge routine. The charger initiates Bulk Charging if connected to AC based on
SOC, the battery type is CC/CV, or if the DC voltage is low (
≤
12.8 VDC / 12-volt models,
≤
25.6
VDC / 24-volt models, or
≤
51.2 VDC / 48-volt models). If the DC voltage is high (
≥
12.9 VDC /
12-volt models,
≥
25.6 / 24-volt models, or
≥
51.2 / 48-volt models), the charger skips the Bulk
and Absorb charging stages and goes directly to the
fi
nal charge stage (Float or Silent).
Figure 5-13, Charging Mode
• Charger
Standby (Chg Stby)
– This indicates the charger has been disabled to prevent
further charging, but the AC power (from utility or generator) to the AC input is still available on
the AC output. This display is shown when the ON/OFF CHARGER button is pressed while the AC
power is passing through the inverter/charger.
Info:
Press ON/OFF CHARGER button to re-enable charging. When enabled, the charger
continues in the previous charge mode and the CHG (green) LED comes on solid.