Appendix B – Compatibility Matrix
Page 158
©
2017 Sensata Technologies
Button
FEATURES/SETTINGS
Model/
Level
Required
Default
Setting
Main Menu
Menu
Heading/Item
Selections/
Adjustments Range
SETUP (Cont.)
01 System
Setup
(Cont.)
01C Power Save
PowerSave= OFF, 1-60 min
≥
Level 1
15 Min
Port LEDs = Auto, OFF
Auto
01D Temp Display
Fahrenheit, Celsius
Fahrenheit
01E Viewing Ports
Auto Scroll = OFF, 1-60 sec
OFF
01F ARTR Aux Relay
Open Volts = 8.0-17.0*
≥
Level 1
10.0V
Close Volts = 8.0-17.0*
14.0V
Open Delay = 0-127 secs,
1-127 mins
10 secs
Close Delay = 0-127 secs,
1-127 mins
10 secs
01G ARTR Relay SOC
Open = 20-100%
≥
Level 4
[6]
50%
Close = 20-100%
100%
01H Max System
Charge Amps
Disabled, 20-2500 ADC
≥
Level 4
Disabled
01I Days to remind
when to EQ
OFF, 1-255 Days
≥
Level 4
OFF
01J Link PT Charge
Settings
YES, NO
≥
Level 4
YES
02 Invert
Setup
02A Search Watts
OFF, 5-50 Watts
≥
Level 1
5 Watts
02B LBCO Volts
9.0-12.2* VDC
≥
Level 2
10.0 VDC
02C AC In – Time
Connect=12:00A-11:45P
≥
Level 3
[1]
6:00AM
6:00PM
Disconnect=12:00A-11:45P
02D AC In – Volts DC
Connect = 9.0-15.9*
≥
Level 3
[1]
11.0V
Disconnect = 9.1-16.0*
14.1V
02E AC – In SOC
Connect = 20-99%
≥
Level 3
[6]
80%
Disconnect = 21-100%
100%
02F Inv Always Power-
Up When DC Connected NO, YES
≥
Level 1
NO
02G Inverter Threshold
to Start Parallel
OFF, 30%-90%
MS-PAE,
MS-PE
60%
03 Charger
Setup
03A AC Input Amps
AC/AC1 Input = 5-60A
≥
Level 1
[1]
30A
AC2 Input = 5-60A
MSH-RE
20A
03B Low VAC Dropout
AC/AC1 Input = 60-100
VAC, UPS Mode
U.S.
Models
80 VAC
AC2 Input = 60-100 VAC,
UPS Mode
MSH-RE
Models
70 VAC
AC Input = 110-190 VAC,
UPS Mode
Export
models
150 VAC
Содержание ME-ARTR
Страница 1: ...ME ARTR Advanced Router Owner s Manual Version 4 0 ...